PURITY ADJUSTMENT

Purity
1. Using the remote controller, make the screen colour
adjustment
green-only. Adjust the contrast control to have a beam
current of about 500 f.tA (14")/700 pA (21").
2. Degauss the cathode ray tube enough with the
Note: Follow the Job Instruction Sheet to ad-
just the magnetic field.
Vertical Bv
: +0.030 mT (0.30 gauss)
Horizontal Bh
: +0.020 mT (0.20 gauss)
See page 10.
3. Keep the purity magnet in the zero magnetic field
in advance. Roughly adjust the convergence.
4. Observe the points "a" and "b", as shown in Fig.
5-1, through a microscope. Adjust the landing to
the rank "A" requirements.
5. Adjust the raster rotation to "0" eastward.
6. Tighten up the deflection coil.screws.
Tightening torque: 108 *20 N (11 lt2 kgf)
l
7. While observing the cathode ray tube corners.
apply the magnet sheet to have the landing at
rank "A".
Note: Before starting this adjustment, warm
up the unit for 30 minutes or longer at
a beam current of over 500 f.rA (14")/
700 pA (21 I').
Note: Set the service switch SlOOl to call the
service mode and press the single-col-
our key on the process remote control-
ler to get the green-only screen.
Each time the single-colour key is pressed, the
l
screen colour changes as follows.
Green-only
Blue-only
screen
screen
screen cleared
Waveform and others
I
Fig. 5-l
Fig. 5-2
Rank "A" (on the
right of the CRT)
Red-only
screen
Fig. 5-3
Rank "A" (on the
left of the CRT)
Whether in the service mode OI
l
not, hold down the single-coloul
key for 1 second or longer ant
the service mode is called.
The TEXT key or the R.G.Cy kel
may be used instead to provide
the single-colour screens.

CONVERGENCE ADJUSTMENT

o. j Adiustina
I
1. Receive the E-2CH (crosshatch pattern) signal.
2. Using the remote controller, call the Normal mode.
STATIC CONVERGENCE
1. Turn the 4-pole magnet to a proper opening an-
gle in order to superimpose the blue and red col-
ours.
2. Turn the g-pole magnet to a proper opening an-
gle in order to superimpose the green colour over
the blue and red colours.
DYNAMIC CONVERGENCE
1. Adjust the convergence on the fringes of the
screen in the following steps.
a) Fig. 6-7: Drive the wedge at point "a" and
swing the deflection coil upward.
b) Fig. 6-2: Drive the wedges at points 'lb" and
c) Fig. 6-3: Drive the "c" wedge deeper and
swing the deflection coil rightward.
d) Fig. 6-4: Drive the "b" wedge deeper and
swing the deflection coil leftward.
2. Fix all the wedges on the cathode ray tube and
apply glass tape over them.
3. Apply lacquer to the deflection yoke lock screw,
magnet unit (purity, 4-pole and 6-pole magnets),
and magnet unit lock screw.
Finally receive the red-only and blue-only signals
and make sure there is no other colour mixed on
the screen.
I
Waveform and others
Fig. 6-i
I
. - _---
. . . . .
: \
\
Fig. 6-2
Fig. 6-3
Fig. 6-4
Wedge "a"
Fig. 6-5
Purity magnet
fig. 6-6