Sanyo SPW-X253GH56 Service Manual page 12

Split system
Hide thumbs Also See for SPW-X253GH56:
Table of Contents

Advertisement

1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
Source
Controller P.C.B. Ass'y
Fan (Number...diameter)
Fan Motor
Model...Nominal output
Source
No. of pole...rpm(230 V, High)
Coil resistance
(Ambient temperature 20 °C)
Safety device
Operating temperature
Run capacitor
Electronic Refrigerant Control Valve
Solenoid control model
Coil resistance (at 20 °C)
Solenoid control valve model
Heat exchanger
Coil
Rows...fin pitch
Face area
Panel
Model No.
Dew proof heater
Auto louver motor
Auto louver motor...Rated
Coil resistance (at 25 °C)
Drain Pump
Rated
Total head & capacity
SPW-X363GH56
220 - 230 - 240 V / 1 phase / 50 Hz
mm
W
rpm.
BRN – WHT
WHT – VLT
VLT – ORG
°C
Open
°C
Close
µF
VAC,
ORG – GRY
RED – GRY
mm
m
2
V, W,
rpm.
V, W
– 13 –
1. Specifications
SPW-X483GH56
CR - X253GH (Microprocessor)
Turbo (1...ø490)
SFG6X - 61A3P...60 W
220 - 230 - 240 V / 1 phase / 50 Hz
6...530
:
71.1
,
ORG – YEL
:
8.7
,
VLT – PNK
:
13.3
,
YEL – BLK
130 ± 8 °C
79 ± 15 °C
440 V, 6µF
EKV - MOZS584E0
:
46
,
YEL – GRY
:
46
,
BLK – GRY
HKV - 30D16
Aluminum plate fin / Copper tube
2...1.7
0.479
PNR - X483GHA
240 V, 31 W
M2LB24ZA12
AC 240 V, 3W, 2.5 rpm
15,620 Ω ± 15%
WP20SL - 21
AC 230 V, 50 Hz, 14.7 W
400 mm, 600 cc/min
: 22.7
: 43.2
1
: 126.7
: 4 6
: 46
SM830033

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents