MH050FXEA2B
Indoor unit
Outdoor unit
MH050FXEA2B
026/035
MH050FXEA2B outdoor unit cannot be connected to the following indoor unit combination.
-MH052FMEA/MH052FUEA/MH052FEEA
CAUTION:
3 m as minimum pipe length: It will reduce
noise and vibration.
This value must be increased at 7.5 meters
in case it is connected just one indoor unit.
300 mm
minimum
600 mm
minimum
Piping length and the height
1 Room max
length
Dimension
20m
Composition
A,B
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
Power supply
Ø, V, Hz
1,220-240, 50
600 mm
minimum
300 mm
minimum
Main power switch
2 Room total max
Max height between
length
indoor unit & outdoor unit
30 m
A+B
Make at least one round:
It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
Piping outside diameter
Unit
026/035
B
A
Max height between
indoor units
15m
7.5 m
(H)
(h)
C
I
OMPLETING THE
NSTALLATION
Outside diameter
Liquid
Gas
1/4"
3/8"
(h)
(H)
7
E-