DZB Series
Function
Name
Code
Input terminal status
Output terminal status
PID setpoint
PID feedback
VI value
CI value
Current segment of
multi-speed control
operation status display
F3.07
0- 14 (0:inv ali d )
p eferential option
r
IGBT module temperature
~
F3.08
0 100 .0
F3.09
Softwa re version
Accumulative op er ating
F3.10
~
0 655 35h
time
The fault be fore previous
:
0 No fault
F3.11
fault type
1:IGBT U phase protection(E009)
F3.12
Previous fault type
2:IGBT V phase protection(E019)
F3.13
Curr en t fault type
3:IGBT W phase protection(E029)
4:Acceleration over-current(E004)
5:Decelera tion over- current(E005)
6:Constant speed over-current
(E006)
7:Acceleration over-voltage(E002)
8:Decelera tion over- voltage(E00A)
9:Constant speed over-voltage
(E003)
10:Bus under-voltage fau lt E 001
11:Motor overload (E007)
12:Inverter overload(E008)
13:Input side phase failur e(E012)
14:Output sid e phase failure(E013)
15:(Diode mo dule overhe at fault
(E00E)
16:IGBT module overheat fa ult
( E0 1E)
17:External faul t(E017)
- 29-
Chapter 5 Function Parameters List
Default
Modifi
Serial
Setting Range
Value
cation
No
4
8
16
32
64
128
256
※
85.
0
℃
**
86.
**
87.
0
88.
**
**
89.
90.
**
91.
**
(
)
DZB Series
Function
Name
Code
18 :Communication fa ult(E01 8)
19 :Current detect e rror( E0 15 )
20 :Motor self-learning error(E016)
21 :EEPROM o peration error
(E00F)
22 :PID feedback di sconne ct er ror
(E02E)
23 :Brak in g unit e rr or E01 A
24 :Reserved
Operating freq uency at
F3.1 4
curre nt faul t
Outp ut amperag e at
F3.15
curre nt faul t
F3.1 6
Bus voltage at curr ent fa ult
Input terminal statu s at
F3.1 7
curre nt faul t
Outp ut terminal statu s at
F3.18
curre nt faul t
F4 Application Function Parameters
~
F4.0 0
ACCEL Time 2
0.1
36 00 .0s
~
F4.01
DECEL Time 2
0.1
36 00 .0s
~
F4.0 2
Jogg ing freq uen cy
0.0 0 F0.04
Jogg ing ACCEL time
~
F4.03
0.1
36 00 .0s
Jogg ing D ECEL time
~
F4.0 4
0.1
36 00 .0s
Skip fre quency
~
F4.05
0.0 0 F0.04
Skip fre quency range
~
F4.0 6
0.0 0 F0.04
~
0.0 10 0.0%
Traverse frequen cy range
F4.0 7
(
relative to se t frequen cy
~
0.0 50 .0%(relative to traverse
Kick frequ ency ran ge
F4.08
frequ ency range)
Traverse frequen cy up
~
F4.0 9
0.1
36 00 .0s
time
Traverse frequen cy dow n
~
F4.1 0
0.1
36 00 .0s
time
~
F4.11
Fault auto -r eset times
0 3
Interval ti me setting of
~
F4.1 2
0.1 100.0s
au tomatic re setting fa ult
- 30-
Chapter 5 Function Parameters List
Default
Modifi
Serial
Setting Range
Value
cation
No
(
)
0.0 0Hz
* *
92.
0.0A
* *
93.
0.0V
* *
94.
0
* *
95.
0
* *
96.
10 .0s
※
97.
10 .0s
※
98.
※
5.0 0Hz
99.
※
10 .0s
100.
※
10 .0s
101.
※
0.0 0Hz
102.
※
0.0 0Hz
103.
※
0.0%
104.
)
※
0.0%
105.
※
5.0s
106.
※
5.0s
107.
※
0
10 8.
※
1.0s
10 9.
www.yusto.ru
info@yusto.ru