Items
Standby / consumed
current
Operation time /
consumption current
accumulated
Clock accuracy
BC level
Bulb battery life
Judgment standard
Main SW / OFF: 250μA or less
(Do NOT press any operational buttons.)
Main SW / ON (Half-release timer: OFF): 250μA or less
Main SW / ON (Half-release timer: ON): 250μA or less
Main SW / ON (Illumination: ON): 300μA or less
Main SW / ON (TFT ON): 1A or less
Lens scan
AF50/1.8  Operation time: 1000 ms or less 
    Consumption current accumulated: 500mAsec or less
AF70-210/4-5.6 Operation time: 2000ms or less
    Consumption current accumulated: 800mAsec or less
 
Preview   Operation time: 200ms or less
    Consumption current accumulated: 120mAsec or less
Release without memory card Operation time: 300ms or less
    Consumption current accumulated: 250mAsec or less
Difference par month: ±30 seconds (20℃)
Level 5: 5 lights up 
Level 4: 4 lights up 
Level 3: 3 lights up 
Level 2: 2 lights up 
Level 1: 1 light up 
Level 0: 1 light blinking Charge remaining: 0%
When special Li-ion is used: 2 and a half hours or more
- R4 ・    -
Charge remaining: 70 ~ 100%
Charge remaining: 50 ~ 69%
Charge remaining: 35 ~ 49%
Charge remaining: 20 ~ 34%
Charge remaining: 1 ~ 19%
VBA14001-R.3694.A
Remarks
Constant-voltage
power source (5A or
more)
Battery tool
(J61213)
Ammeter
AF50/1.4
EV12
Constant voltage
power source (5A or
more)
Battery tool
(J61210)
Special tool
Oscilloscope
LV12
Wave clock
Check the level in
the LCD control
panel on top of
camera or TFT
battery information
Communication-
capable battery tool
Clock
Remote wire