D Auto Operation - Mitsubishi Heavy Industries SRK20ZJ-S Data Book

Inverter wall mounted type room air-conditioners
Hide thumbs Also See for SRK20ZJ-S:
Table of Contents

Advertisement

6. 3D auto operation

Control the flap and louver by D AUTO button on the wireless remote controller.
Air f low selection and air flow direction are automatically controlled, allowing the entire indoor to efficiently conditioned.
(1) During Cooling and Heating (Including auto cooling and heating)
(a) Air f low selection is determined according to indoor temperature and setting temperature.
Operation mode
At cooling
At heating
(b) Air f low direction is controlled according to the indoor temperature and setting temperature.
)
When D auto operation starts
Flap
Louver
)
When Indoor temp. – Setting temp. is
heating, the system switches to the following air f low direction control. After the louver swings left and right sym-
metrically for  cycles, control is switched to the control in ).
Flap
Louver
)
After the flap swings for  cycles, control is switched to the control in ).
Flap
Louver
)
For  minutes, the following air flow direction control is carried out.
Flap
Louver
)
After  minutes have passed, the air f low direction is determined according to the indoor temperature and setting
temperature.
Operation mode
At cooling
At heating
(2) During DRY Operation (including auto DRY operation)
Air flow selection
Flap
Louver
Indoor temp. – Setting temp. >5°C
HIGH POWER
Setting temp. – Indoor temp. >5°C
HIGH POWER
Cooling
Up/down Swing
Wide (Fixed)
< =
ºC during cooling and when Setting temp. – Indoor temp. is
Cooling
Horizontal blowing (Fixed)
Left/right Swing
Cooling
Up/down Swing
Cooling
Horizontal blowing (Fixed)
< =
Indoor temp. – Setting temp. 2°C
The control in 4) continues.
< =
Setting temp. – Indoor temp. 2°C
The control in 4) continues.
According to DRY operation.
Horizontal blowing (Fixed)
Air flow selection
AUTO
Indoor temp. – Setting temp. 5°C
AUTO
Setting temp. – Indoor temp. 5°C
AUTO
Heating
Center (Fixed)
Heating
Slant forwardl blowing (Fixed)
Heating
Center (Fixed)
Heating
Slant forwardl blowing (Fixed)
Wide (Fixed)
Air flow direction contorol
2°C < Indoor temp. – Setting temp. 5°C
Control returns to the control in 2).
2°C < Setting temp. – Indoor temp. 5°C
Control returns to the control in 2).
Wide (Fixed)
0
-
-
'09•SRK-DB-087D
HI
MED
< =
HI
MED
< =
< =
< =
Indoor temp. – Setting temp. > 5°C
Control returns to the control in 1).
< =
Setting temp. – Indoor temp. > 5°C
Control returns to the control in 1).
LO
LO
ºC during

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk25zj-sSrk35zj-s

Table of Contents