White Balance Adjustment - FUNAI Sylvania LC260SS1 Service Manual

26" lcd tv
Table of Contents

Advertisement

The White Balance Adjustment should be
performed when replacing the LCD Panel
or Digital Main CBA.

3. White Balance Adjustment

Purpose: To mix red, green and blue beams correctly
for pure white.
Symptom of Misadjustment: White becomes bluish
or reddish.
Test Point Adj. Point
[VOL Y]
Screen
button
M. EQ.
Pattern Generator,
Color analyzer
Figure
To avoid interference from ambinent
light, this adjustment should be
performed in a dark room.
Perpendicularity
L = 3 cm
INPUT: WHITE 70%, 40%
1. Operate the unit for more than 20 minutes.
2. Input the White Raster(70%=70IRE, 40%=40IRE).
INPUT SIGNAL
0IRE
Low
Light
100IRE
40%=40IRE
3. Set the color analyzer to the CHROMA mode and
bring the optical receptor to the center on the
LCD-Panel surface after zero point calibration as
shown above.
Note: The optical receptor must be set
perpendicularly to the LCD Panel surface.
4. Enter the Service mode. Press [VOL Y] button on the
remote control unit and select "C/D" mode.
Mode
Input
White Raster
[VIDEO1]
(APL 70%)
C/D
or
(APL 40%)
Spec.
x= 0.272 ± 0.005
y= 0.278 ± 0.005
Color Analyzer
0IRE
Hight
Light
100IRE
70%=70IRE
5. [CUTOFF]
Press [1] button to select "COR" for Red Cutoff
adjustment. Press [3] button to select "COB" for
Blue Cutoff adjustment.
[DRIVE]
Press [4] button to select "DR" for Red Drive
adjustment. Press [6] button to select "DB" for Blue
Drive adjustment.
6. In each color mode, press [CH X/Y] buttons to
adjust the values of color.
7. Adjust Cutoff and Drive so that the color
temperature becomes 12000°K (x= 0.272 / y=
0.278 ±0.005).
8. To cancel or to exit from the White Balance
Adjustment, press [PREV CH] button.
5-3
FL10.2EA