Pilot Flame Characteristics - Empire Comfort Systems VFDR18LBW10N-4 Installation Instructions And Owner's Manual

Vented/vent-free burner and logs
Hide thumbs Also See for VFDR18LBW10N-4:
Table of Contents

Advertisement

Figures 19 and 20 show a correct pilot flame pattern. The correct
flame will be blue and will extend beyond the thermocouple. The
flame will surround the thermocouple just below the tip. A slight
yellow flame may occur where the pilot flame and main burner
flame meet. Figures 21 and 22 show an incorrect pilot flame pattern.
The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the
heater will shut down.
Correct Pilot Flame Pattern for VFDR
Correct Pilot Flame Pattern for VFDT & VFDM
30726-4-0714

PILOT FLAME CHARACTERISTICS

Figure 19
Figure 20
Incorrect Pilot Flame Pattern for VFDR
Incorrect Flame Pattern for VFDT & VFDM
If pilot flame pattern is incorrect, as shown in Figures 21 and 22
See Troubleshooting, page 31.