INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installing Optional Blower
1. Remove rear shield (2 screws) and bottom reflector (4 screws).
(See Figure 1)
2. Align blower cushion with bottom assembly air discharge
opening. Foil face side of blower cushion should be placed
upward.
3. Align blower housing with blower cushion and use two, #10
x 1/2" (13mm )hex-head screws to attach blower housing to
bottom assembly. (See Figure 2)
4. Save bottom reflector and rear shield (removed in Step 1) in the
event the blower housing is removed from room heater.
Attention! Bottom reflector and rear shield must be attached
to bottom assembly whenever the blower housing is removed
from the room heater and the room heater is in operation.
5. Remove switch box cover from the switch box by removing
the #8 x 1/4" (6mm) hex-head screw.
6. There are two screw holes on the lower back of the combus-
tion chamber. Use only the left screw hole for mounting.
7. With the switch box perpendicular to the combustion chamber,
align the round clearance hole on the switch box with the
left screw hole on the combustion chamber. (See Figure 3)
8. Attach switch box to the combustion chamber using the #10
x 1/2" (13mm) hex- head screw provided.
9. Attach switch box cover to the switch box by using the #8
x 1/4" (6mm) hex- head screw. (See Figure 4)
R-2606-1-1001
OPTIONAL BLOWER ASSEMBLY
INSTALLATION INSTRUCTIONS
R-2606
EFFECTIVE DATE OCTOBER, 2001
Figure 1
OPTIONAL BLOWER
FRB-3
Vented Room Heaters
Models RH-50 and RH-65
RH-50C and RH-65C
Figure 2
Figure 3
Figure 4
Page 1

Advertisement

loading

Summary of Contents for Empire Comfort Systems RH-50

  • Page 1 OPTIONAL BLOWER OPTIONAL BLOWER ASSEMBLY FRB-3 INSTALLATION INSTRUCTIONS Vented Room Heaters R-2606 Models RH-50 and RH-65 EFFECTIVE DATE OCTOBER, 2001 RH-50C and RH-65C INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION Figure 2 Figure 1 Installing Optional Blower 1.