Chapter 5 Charging Faults - Nokia 3510 Repair Manual

Hide thumbs Also See for 3510:
Table of Contents

Advertisement

Customer Care Europe, Middel East & Africa
SCCE Training Group
 2003 Nokia Mobile Phones
CHAPTER 5: Charging Faults
battery size failed
Check BSI-line for shorts
to GND, check C747, L710
or change X101.
In case the charging of battery fails, first thing to do is to run energy management calibration.
Note that calibration only works with JBV-1, MJF-16 docking station adapter and 12VDC power supply.
In case charging does not work permanently or charging is possible from time to time only, especially check spring contacts of
bottom connector I007 and battery connector I010 if bent, soiled or corroded. Also make sure that contact pads for the
connectors on the PCB are clean. If necessary clean the PCB with an appropriate amount of alcohol. Do not use any scratching
or rubbing tools!
Whenever a part has been changed in the charging circuit, you have to run energy management calibration to ensure a proper
function of the phone!
I007 / I010
Check mechanical appearance of battery connector and bottom connector; change parts if spring contacts are bent,
-
soiled or corroded. Also ensure that contact pads for both connectors on the PCB are clean.
F100
-
Check resistance of fuse; must be zero Ohm.
V100
-
Check that V100 does not cause a short circuit to ground. Resistance of VCHAR-line to ground normally is 2.6kOhm.
D200
If all steps above are checked, probably UEM (D200) is faulty. Swap the phone because UEM is underfilled and
-
therefore not changeable.
© NMP 2003
battery temperature failed
Check BTEMP-line for shorts to
GND, check C746, L711 for cold or
broken soldering or
change X101.
CONFIDENTIAL
NHM-8 / RH-9
Date 10-03-2003
Charging not
possible
Run energy
Try to charge after
management
OK
calibration.
nOK
battery voltage failed
charge voltage failed
UEM D200 faulty
in all probability.
check / change X101.
Check F100, L100, V100 and C100
for cold or broken soldering. Or
shorts to GND, if failure persists
UEM is faulty .
Checked by: SCCE
Repairhints
Version 2.0 Approved
calibration.
charge current failed
Check resistance of R200
(0.22 Ohm).
UEM D200 is faulty.
Approved by: Training Group
13 (18)