Appliance Details - Bosch 940 ESO Installation Manual

For outdoor installations only temperature modulated with electronic ignition suitable for heating potable water and space heating (intended for variable flow applications)
Hide thumbs Also See for 940 ESO:
Table of Contents

Advertisement

2

Appliance details

2.1
Features
Parts
Key Pad interface control
• High power pre-mix compact burner with low NOx
emissions
• Modulating Gas Valve with constant gas:air ratio
control
• Modulating water valve for improved comfort and
temperature control.
High quality materials for long working life
• Copper heat exchanger
• High efficiency Ceramat Burner
• Compact space saver: mounts on a wall with a
supplied bracket.
Features
• Real-time
diagnostics
informational purposes
• LCD Display with backlight
• On/Off and Temperature control switches
• Reset button
• Program button (Selectable temperature default)
• Failure codes for easy diagnostics and repair
• Easily removable one-piece cover
• Built in freeze prevention
Accessories (Bosch part #)
• Optional wireless remote control accessory to
operate with the appliance (TSTAT2)
• Cascading kit (7709003962)
• External water filter (8703305356)
• Gas conversion kit (8719002176)
• Pipe Cover (PTPCES)
• Recess box (7736500043)
• Pressure relief valve (FWL-2).
BOSCH is constantly improving its
i
products, therefore specifications are
subject to change without prior notice.
1) The freeze prevention kit is designed to provide
protection for the water heater down to approximately
5°F for short term conditions only. It will not protect the
appliance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention kit will not protect plumbing
outside the appliance from freezing. Precautions should
be taken.
6 720 644 956
for
troubleshooting/
1)
.
2.2
Specifications (Technical data)
Approved in US/Canada
Capacity
Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F
(25°C) rise.
Maximum output
160,500 Btu/h (47.0 kW)
Maximum input
199,000 Btu/h (58.3 kW)
Efficiency in %
Thermal efficiency > 82%
Min. Input
19,900 Btu/h (5.8 kW)
Temperature Control
Selection range: 100°F (38°C) - 140°F (60°C)
Default temperature: 122°F (50°C)
Stability: +/- 2°F (+/- 1°C)
Gas Requirement
Gas connection (inches) - ¾"
Inlet gas pressure under operation (with a high hot
water flow rate)*
• Propane: 8" - 13" water column
• Natural Gas: 3.5" - 10.5" water column.
* To measure gas pressure, see Measuring Gas
Pressure, chapter 6.6, page 24.
Water
• Hot water connection (inches) - ¾"
• Cold water connection (inches) - ¾"
• Water valve material: Polymer (PPS) (Polypropylene
Sulfid)
• Minimum water flow: 0.5 gallon/minute (1,9 l/m).
Note: Activation varies with inlet water temperatures
from 0.5 - 1.6 gallon/minute (1.9 - 6.1 l/m).
• Minimum recommended water pressure: 30 PSI
(2.07 bar).
• Minimum well pressure 40 psi, see page 20.
• Connections:
– Bottom of heater
Combustion
• NOx ≤ 40 Ng/J
(Nanograms of NOx (calculated as NO 2 ) per
Joule of heat output).
• CO ≤ 250 ppm (measured)
• CO
level set from factory, see chapter 9.4, page 33.
2
Appliance details
5

Advertisement

Table of Contents
loading