8.1.2 Semi standard – IP54 with integral EMC filter and DCR
Item
Type (FRN? ? ? F1L-4E)
Nominal applied motor [kW]
*1)
Rated capacity [kVA]
Rated voltage [V]
*3)
Rated current [A]
*4)
Overload capability
Rated frequency
Main power supply
Auxiliary control
power input
Auxiliary power input
for the fans
*9)
Voltage/frequency
variations
Rated current [A]
*5)
Required power supply
capacity [kVA]
*6)
Torque
[%]
*7)
DC injection
braking
EMC filter
DC REACTOR (DCR)
KEY PAD
Applicable safety standards
Enclosure
Cooling method
Weight / Mass [kg]
Note
*1) Fuji's 4-pole standard motor
*2) Rated capacity is calculated by regarding the output rated voltage as440V for three-phase 400V series.
*3) Output voltage cannot exceed the power supply voltage.
*4) Motor temperature gets higher or current limit function of the inverter is easy to operate if carrier frequency is set to
low. Continuous or peak load shall be reduced to avoid high motor temperature or current limit operation.
When setting the carrier frequency (F26) to 1 kHz or below, reduce the load to 80% of rated load or below for use.
*5) Calculated under Fuji-specified conditions.
*6) Obtained when a DC REACTOR is used.
*7) Average braking torque without optional braking resistor (Varies with the efficiency of the motor.)
=
*8)
Voltage
unbalance
If this value is 2 to 3%, use an AC REACTOR.
*9) Normally no need to be connected. Use these terminals when the inverter is used with a power regenerative PWM
converter (e.g. RHC series).
Chapter 8: Specifications and External Dimensions
0.75 1.5
2.2
3.7
0.75 1.5
2.2
3.7
1.9
2.8
4.1
6.8
*2)
Three-phase 380V,400V/50Hz, 380V,400V,440V,460V/60Hz (With AVR function )
2.5
3.7
5.5
9.0
120% of rated current for 1min
50, 60Hz
Three-phase,380 to 480V,50/60Hz
Single-phase,380 to 480V,50/60Hz
Voltage: +10 to -15% (Voltage unbalance: 2% or less
1.6
3.0
4.5
7.5
1.2
2.2
3.1
5.3
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%
Standard conformance: Immunity: 2
Emission: Class A Group 1 (EN55011: 1998+A1: 1999+A2: 2002)
Input power factor : 86% or more at 100% load(Output Rating)
Multifunctional Keypad (TP-G1)
UL508C, C22.2No.14, EN50178:1997(Applying)
IP54(IEC60529) / UL TYPE 12(UL50)
Natural
cooling
12.5 12.5
13
14
Max.
voltage
[V]
Min.
voltage
Three
-
phase
average
voltage
Specifications
5.5
7.5
11
15
18.5
5.5
7.5
11
15
18.5
9.5
12
17
22
12.5 16.5
23
30
-
), Frequency: +5 to -5%
*8)
10.6 14.4 21.1 28.8 35.5 42.2 57.0 68.5 83.2 102
7.4
10
15
20
20
Env. (EN61800-3: 1996+A11:2000)
nd
Fan cooling
14
22
22
24
[V]
×
67%
(IEC61800
[V]
22
30
37
45
22
30
37
45
28
33
44
54
64
37
44
59
72
85
Three-phase,
380 to 440V/50Hz
380 to 480V/60Hz
Single-phase,
380 to 440V/50Hz
380 to 480V/60Hz
25
30
40
48
58
34
35
40
54
56
3(5.2.3))
55
75
90
55
75
90
77
105
128
105
139
168
Single-phase,
380 to 440V/50Hz
380 to 480V/60Hz
138
164
71
96
114
10 to 15
74
76
86
26