Rinnai REU-V3237FFU Operation & Installation Manual page 47

Residential and commercial for indoor and outdoor unit
Hide thumbs Also See for REU-V3237FFU:
Table of Contents

Advertisement

1)
Determine a suitable location for the
controller.
2)
Make three holes in the wall as shown.
3)
Run the cable between the controller and
the Rinnai Water Heater or the controller
and the other controller.
4)
Remove the face plate from the remote controller, using a screw driver.
5)
Connect the cable to the remote controller.
6)
Mount the controller to the wall using the holes drilled in step 2.
7)
Disconnect the power from the Rinnai Water Heater.
8)
Remove the cover of the Rinnai Water Heater.
9)
Remove the plastic cover from the PCB and electrical connections.
DO NOT ATTEMPT TO CONNECT THE REMOTE CONTROLLERS WITH THE
POWER ON; THERE IS 120 VOLT POTENTIAL, NEXT TO THE REMOTE
CONTROLLER CONNECTIONS INSIDE THE UNIT. DO NOT CONNECT THE
REMOTE CONTROLLER TO THE 120VAC TERMINALS PROVIDED FOR THE
OPTIONAL SOLENOID DRAIN VALVES. All service and wiring should be
performed by a registered installer.
10) Thread the cable through the
access hole at the base of the
unit and connect the wires to the
controller terminals on the right
hand side bottom of the PCB.
11) Secure the controller cable using
the clamp provided.
12) Replace plastic cover over PCB and
then replace the cover of the Rinnai
Water Heater.
Rinnai Corporation
REMOTE CONTROLLERS INSTALLATION
securing screw
wiring hole
securing screw
47
Outline of Remote
1-21/32˝
V3237 Models
3-5/16˝