Procedures; Verifying Proper Dipswitch Settings - A.O. Smith 110 Troubleshooting Manual

110/310/510 indoor/outdoor non‐condensing on‐demand water heater
Table of Contents

Advertisement

 
 
5.4 TROUBLESHOOTING ‐ PROCEDURES 
Verifying proper Dipswitch settings...
Draining the unit....................................p.21 
Cleaning the filter..................................p.21 
Checking for a Cross Connection.........p.21 
Check for Reverse Connection.............p.21 
Check gas supply pressure...................
Purge the gas line of air.......................
Adjusting manifold pressure................p.22 
Resetting the computer board............
Checking the OHCF............................... p.24
 
VERIFYING PROPER DIPSWITCH SETTINGS:  
Incorrect Dipswitch settings can cause a 031 error code, or a number of operational problems. 
 
Table 3 – 310 (T‐K4), 110 (T‐KJr2) Dipswitch Settings 
No. 
Gas type 
FM+, FM++, FM+++            110 Indoor (T‐KJr2‐IN), 310 Indoor (T‐K4‐IN) 
N/A 
Model type 
Output temperature settings (Default 122F) 
p.19 
 
p.21 
 
p.22 
  
p.23 
 
Function 
 
No.4 
OFF position 
ON position 
110 Outdoor (T‐KJr2‐OS), 310 Outdoor (T‐K4‐OS) 
 
No.4 
OFF position 
ON position 
19|
Dipswitch Bank 
Figure 15
ON position 
Propane 
Natural Gas 
No.3 
OF  position 
0% 
+12% 
No.3 
OFF position 
ON position 
0% 
+8% 
   
N/A 
Outdoor 110 (T‐KJr2‐OS), 
Outdoor 310 (T‐K4‐OS) 
 Page 
 
Troubleshooting Guide 
OFF position 
Disable 
Disable 
N position 
+6% 
+18% 
+4% 
+12% 
N/A (Default) 
Indoor 110 (T‐KJr2‐IN), 
Indoor 310 (T‐K4‐IN) 