AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model
No.
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-036-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
XC16-048-230 + TXV
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitutions Table.
XC16 - 2 to 5 Ton Heat Pump / Page 16
Capacity
SEER
EER
35,600
16.00
11.50
35,400
16.00
11.50
35,400
16.20
12.00
36,200
16.20
12.00
36,200
16.20
11.70
36,200
16.00
12.00
36,200
16.20
12.00
35,400
16.00
11.50
35,400
16.20
12.00
36,200
16.20
12.00
36,200
16.00
12.00
35,200
14.20
11.00
35,400
16.20
11.70
36,000
16.20
11.70
35,800
16.20
11.70
35,200
15.70
11.20
35,000
15.70
11.50
35,200
15.70
11.20
35,200
16.00
11.70
35,600
16.00
11.70
35,800
16.00
11.50
35,600
15.70
11.70
35,600
16.00
11.70
35,000
15.70
11.50
35,200
16.00
11.70
35,600
16.00
11.70
35,600
15.70
11.70
34,800
14.20
10.90
35,600
14.50
11.00
45,500
15.00
11.70
45,500
14.70
11.50
45,500
14.50
11.50
45,500
14.70
11.20
45,500
14.50
11.50
45,500
14.50
11.50
46,000
15.00
11.70
45,500
15.00
11.70
45,500
14.50
11.50
45,000
14.20
11.20
45,500
13.70
11.20
45,500
14.70
11.20
45,500
14.50
11.50
Coil or
Furnace
Air Handler
CX34-43
G61MPV-36B-045
CX34-43
G61MPV-36B-070
CX34-43
G61MPV-36C-090
CX34-43
G61MPV-60C-090
CX34-43
G61MPV-60C-091
CX34-43
G61MPV-60C-110
CX34-43
G61MPV-60C-111
CX34-43
G71MPP-36B-070
CX34-43
G71MPP-36C-090
CX34-43
G71MPP-60C-090
CX34-43
G71MPP-60C-110
CX34-43
CX34-44/48
G60UHV-36B-090
CX34-44/48
G60UHV-60C-090
CX34-44/48
G60UHV-60C-110
CX34-44/48
G61MPV-36B-045
CX34-44/48
G61MPV-36B-070
CX34-44/48
G61MPV-36B-071
CX34-44/48
G61MPV-36C-090
CX34-44/48
G61MPV-60C-090
CX34-44/48
G61MPV-60C-091
CX34-44/48
G61MPV-60C-110
CX34-44/48
G61MPV-60C-111
CX34-44/48
G71MPP-36B-070
CX34-44/48
G71MPP-36C-090
CX34-44/48
G71MPP-60C-090
CX34-44/48
G71MPP-60C-110
CX34-44/48
CX34-49
C33-44C
G60UHV-60C-090
C33-44C
G61MPV-60C-090
C33-44C
G61MPV-60C-110
C33-44C
G61MPV-60C-091
C33-44C
G61MPV-60C-111
C33-44C
G71MPP-60C-110
C33-48
G60UHV-60C-090
C33-48
G60UHV-60C-110
C33-48
G61MPV-60C-110
C33-48
O23V5-140/154
C33-48
C33-48
G61MPV-60C-091
C33-48
G61MPV-60C-111
AHRI
Reference
3068672
3068673
3068675
3068677
3068679
3068680
3068682
3068674
3068676
3068678
3068681
3068635
3068683
3068757
3068684
3068685
3068686
3068688
3068689
3068691
3068693
3068694
3068696
3068687
3068690
3068692
3068695
3068636
3068637
1003984
1003983
1003988
1046650
1046651
1488411
1003987
1003990
1003986
1038249
1003999
1046652
1046653

Hide quick links: