OIL-FIRED CENTRAL FURNACE Installation, Operation, and Service Manual With Users Information Section Models: CSHB60-90XE CSHB60-90XP c WARNING: • Do NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • Improper...
I. SAFETY SECTION This page contains various warnings and cautions found throughout the Oil Furnace Manual. Please read and comply with the statements below. cWARNING AND CAUTIONS: cWARNING: This furnace is not to be used as a construction heater. See Page 1. c CAUTION MUST BE TAKEN NOT TO EXCEED 90°...
All installations and services must be performed by qualified service personnel. TABLE OF CONTENTS SECTION BEGINNING PAGE I. SAFETY SECTION II. GENERAL INSTRUCTIONS A. VENTING B. DRAFT REGULATORS C. DUCT WORK/AIR CONDITIONING D. FILTERS MOUNTED EXTERNAL TO FURNACE E. LIMIT POSITION AND LOCATION F.
All installations and services must be performed by qualified service personnel. II. GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION 1. The heating output capacity of the furnace proposed for installation should be based on a heat loss calculation made according to the manuals provided by the Air Conditioning Contractors of America (ACCA) or the American Society of Heating, Refrigeration and Air Conditioning Engineers, Inc.
All installations and services must be performed by qualified service personnel. Power (Side-Wall) Venting-Important Note Regarding cCAUTION: Crown Boiler Company will NOT assume responsibility for damage to, and deterioration of, exterior building materials, e.g. brick, siding, clapboards, and etc., in close proximity to the vent terminal due to operation of a power vented, oil furnace.
Page 6
All installations and services must be performed by qualified service personnel. SIDE WALL VENTING APPLICATION ORDER INFORMATION FIELD VENT COMBUSTION AIR TERMINATION KIT INTAKE KIT (15’ application MAX) (FOR COMBUSTION AIR APPLICATIONS ONLY) BURNER PART NUMBER PART NUMBER Beckett AFG 160930 160945 Beckett NX...
All installations and services must be performed by qualified service personnel. B. DRAFT REGULATORS: A draft regulator is supplied with the furnace and should be installed according to the regulator manufacturers recommendations. With the burner operating, use a draft gauge to adjust the regulator to the proper setting. (refer to the instructions enclosed with draft regulator to adjust to the proper setting).
All installations and services must be performed by qualified service personnel. PLEASE NOTE: While scribing the return air opening, the filter rack can be held in position by tape or similar temporary means. Fig. 2: A typical filter rack and dimensions for the CSHB60-90 furnace. Position the open end of the filter rack so as to provide access for filter replacement.
All installations and services must be performed by qualified service personnel. F. BURNER INSTALLATION: NOTICE: Remove all cardboard packing from around chamber before installing burner. The oil burner will mount on three stud mounting bolts on the lower mounting plate covering the opening in the front of the heat exchanger.
All installations and services must be performed by qualified service personnel. G. BURNER SPECIFICATIONS AND APPLICATIONS FURNACE MODEL BURNER BURNER HEAD STATIC MAXIMUM SHIPPED CSHB60-90 SPEC MODEL & TUBE PLATE NOZZLE NOZZLE PUMP LENGTH SIZE** SIZE PRESSURE BURNER (PSIG) BECKETT (AFG) 130200S AFG-4.5”...
All installations and services must be performed by qualified service personnel. H. HEAT EXCHANGER CLEANING INSTRUCTIONS: c WARNING: THE HEAT EXCHANGER MUST BE CLEANED BY A QUALIFIED SERVICE PERSON. It is important to inspect and clean the heat exchanger once a year, or as necessary, to remove any build-up of soot. A layer of soot on the inside of the heat exchanger will act as an insulator and reduce heat transfer, resulting in less efficiency.
All installations and services must be performed by qualified service personnel. III. USERS INFORMATION SECTION A. OIL SUPPLY: Do not allow the fuel tank to run completely empty. During the summer, keep the tank full to prevent condensation of moisture on the inside surface of the tank. If the fuel tank runs completely dry, it may be necessary to purge the lines of trapped air.
All installations and services must be performed by qualified service personnel. E. FILTER CLEANING AND LOCATION: The air filters should be inspected each month and cleaned when dirty. Cleaning the air filters frequently may reduce airborne contaminants from entering the furnace and depositing in the furnace, duct system and home. c WARNING: To avoid injury from moving parts, hot surfaces, or electrical shock, shut off the power to the furnace before removing any furnace access doors to service the air filters.
All installations and services must be performed by qualified service personnel. APPENDIX-B Wiring Diagrams BLOWER SPEED TAPS COOL = A/C Tap HEAT = Heating Tap LOW = Constant air or Dehumifier...
Page 16
All installations and services must be performed by qualified service personnel. All installations and services must be performed by qualified service personnel. 13 13...