TROUBLESHOOTING
Temperature Sensor Data:
Temp.
Temp.
°F
°C
14
-10
16
-9
18
-8
19
-7
21
-6
23
-5
25
-4
27
-3
28
-2
30
-1
32
0
34
1
36
2
37
3
39
4
41
5
43
6
45
7
46
8
48
9
50
10
52
11
54
12
55
13
57
14
59
15
61
16
26
Resistance
Temp.
°F
62.3
63
58.7
64
56.4
66
52.2
68
49.3
70
46.6
72
44.0
73
41.6
75
39.8
77
37.2
79
35.2
81
33.3
82
31.6
84
30.0
86
28.3
88
26.9
90
25.5
91
24.2
93
22.6
95
21.8
97
20.7
99
19.7
100
18.7
102
17.8
104
16.9
106
16.1
108
15.3
109
Temp.
Resistance
°C
17
14.6
18
13.9
19
13.3
20
12.6
21
12.1
22
11.5
23
11.0
24
10.5
25
10.0
26
9.6
27
9.1
28
8.7
29
8.3
30
8.0
31
7.6
32
7.3
33
7.0
34
6.7
35
6.4
36
6.1
37
5.9
38
5.6
39
5.4
40
5.2
41
5.0
42
4.8
43
4.6
Temp.
Temp.
Resistance
°F
°C
111
44
113
45
115
46
117
47
118
48
120
49
122
50
124
51
126
52
127
53
129
54
131
55
133
56
135
57
136
58
138
59
140
60
142
61
144
62
145
63
147
64
149
65
151
66
153
67
154
68
156
69
158
70
4.4
4.2
4.0
3.9
3.8
3.6
3.5
3.3
3.2
3.1
3.0
2.8
2.7
2.6
2.5
2.4
2.4
2.3
2.2
2.1
2.0
2.0
1.9
1.8
1.8
1.7
1.6