Sanyo XS1271 Instruction Manual

Inverter-controlled split system air conditioner
Hide thumbs Also See for XS1271:

Advertisement

XS1271
XS1872
COOL/DRY Model
This air conditioner uses
the new refrigerant R410A.
108
Pub.
OI-85264181
© SANYO 2008
000
INSTRUCTION MANUAL
Inverter-Controlled Split System Air Conditioner
Climatiseur de type séparé contrôlé par inverseur
Save These Instructions!
Conserver ce mode d'emploi
MODE D'EMPLOI

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo XS1271

  • Page 1 XS1271 XS1872 COOL/DRY Model INSTRUCTION MANUAL Inverter-Controlled Split System Air Conditioner MODE D’EMPLOI Climatiseur de type séparé contrôlé par inverseur This air conditioner uses the new refrigerant R410A. Save These Instructions! Conserver ce mode d’emploi Pub. OI-85264181 © SANYO 2008...
  • Page 2: Table Of Contents

    FEATURES This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner. • Microprocessor Controlled Operation • Automatic and 3-step Fan Speed The interior compartment of the remote control unit Auto/High/Medium/Low contains several features to facilitate automatic operation,...
  • Page 3: Product Information

    PRODUCT INFORMATION ELECTRICAL REQUIREMENTS If you have problems or questions concerning your Air Conditioner, you will need the following information. Model 1. All wiring must conform to the local electrical codes. and serial numbers are on the nameplate on the bottom of Consult your dealer or a qualified electrician for details.
  • Page 4: Names Of Parts

    NAMES OF PARTS UNIT DISPLAY AND OPERATION BUTTON INDOOR UNIT INDOOR UNIT Air intakes OPERATION button OPERATION lamp Air outlet TIMER lamp (4 locations) HIGH POWER lamp REMOTE CONTROL receiver Remote control unit IMPORTANT Refrigerant tubes Avoid using radio equipment such as mobile phone near (within OUTDOOR UNIT 4 ft.
  • Page 5 REMOTE CONTROL UNIT (DISPLAY) Displayed when transmitting data Displayed when indoor unit sensor is in use Displayed when setting temperature Displayed when temperature is shown Displayed when setting timer Displayed when the time display is set to 12-hour time. Symbols (1) Operation mode (4) Timer MILD DRY ......
  • Page 6 REMOTE CONTROL UNIT Transmitter When you press the buttons on the remote control unit, the mark appears in the display to transmit the setting changes to the receiver in the air conditioner. Display Information on the operating conditions is displayed while the remote control unit is switched on.
  • Page 7 Sensor A temperature sensor inside the remote control unit senses the room temperature. ON/OFF operation button This button is for turning the air conditioner on and off. 1 HR. TIMER button (1-HOUR OFF TIMER) : When you press this button, regardless of whether the unit is operating or stopping, the unit operates for one hour and then shuts down.
  • Page 8: Using The Remote Control Unit

    USING THE REMOTE CONTROL UNIT HOW TO INSTALL BATTERIES REMOTE CONTROL UNIT INSTALLATION POSITION The remote control unit may be operated either from a non-fixed position or from a wall-mounted position. To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places: DO NOT •...
  • Page 9: Operation With The Remote Control Unit

    OPERATION WITH THE REMOTE CONTROL UNIT 1. Operation 2. Adjusting the Fan Speed A. Automatic fan speed Simply set the FAN SPEED selector button to the position. This automatically sets the best fan speed for the room temperature. B. Manual fan speed If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired.
  • Page 10: Night Setback Mode

    4. Night Setback Mode HIGH POWER mode can be used to increase the output of the indoor unit for all operation modes except automatic operation. Press the HIGH POWER button while operation. mark appears in the display. To cancel, press HIGH POWER button again. •...
  • Page 11 1. How to set the present time Operation Indication (Example) To set to 10:30 pm. Press the ON TIME setting The timer indication is button once. displayed, and the present ON time is shown. Press the Advance, Return The timer indication ) button until AM 7:10 blinks.
  • Page 12: Using The 1-Hour Off Timer

    USING THE 1-HOUR OFF ADJUSTING THE AIRFLOW TIMER DIRECTION The vertical airflow can be adjusted by moving the flap with the 1. 1-Hour OFF Timer remote control unit. Do not move the flap with your hands. Confirm that the remote control unit has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.
  • Page 13: Operation Without The Remote Control Unit

    OPERATION WITHOUT THE CARE AND CLEANING REMOTE CONTROL UNIT • Cleaning and maintenance operations must be carried out by specially INDOOR UNIT trained personnel. While working in high places, slipping or falling may result in serious injury. • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.
  • Page 14 Air filter How to remove the air intake grille The air filter collects dust and other particles from the air and should Open the air intake grille. be cleaned once every 6 months. Detach the safety cord from the frame (remember to attach it If the filter gets blocked, the efficiency of the air conditioner drops again after cleaning or maintenance).
  • Page 15: Troubleshooting

    TROUBLESHOOTING OPERATING RANGE If your air conditioner does not work properly, first check the following The air conditioner is operable within the temperature ranges as points before requesting service. If it still does not work properly, listed below: contact your dealer or service center. For Cooling Only Models : C1271, C1872 Temperature Indoor air...
  • Page 16 “COOL/DRY Model” indoor unit. Before using the remote controller, be sure to confirm the “model type” specified on the front cover of the INSTRUCTION MANUAL supplied with the indoor unit. Save These Instructions! Conserver ce mode d’emploi Pub. OI-85264181 © SANYO 2008...
  • Page 17 CONTENTS Page PRODUCT INFORMATION ........................ 2 ALERT SYMBOLS ..........................2 INSTALLATION LOCATION ........................ 2 ELECTRICAL REQUIREMENTS......................2 SAFETY INSTRUCTIONS ........................2 REMOTE CONTROL UNIT......................... 4 OPERATION WITH THE REMOTE CONTROL UNIT ................ 6 1. Automatic Operation (only for COOL/DRY/HEAT Model) ............ 6 2.
  • Page 18 REMOTE CONTROL UNIT (DISPLAY) Displayed when indoor unit sensor is in use Displayed when operating NIGHT SETBACK mode Displayed when setting temperature Displayed when temperature is shown Displayed when setting timer Symbols (1) Operation mode (3) Temperature setting 60 – 86 °F ......AUTO ........
  • Page 19: Remote Control Unit

    REMOTE CONTROL UNIT NOTE The descriptions on the AUTO ( ) or HEAT ( ) operation mode are only for the “COOL/DRY/HEAT Model,” and not for the “COOL/DRY Model.” Display Information on the operating conditions is displayed while the remote control unit is switched on.
  • Page 20 ON/OFF operation button This button is for turning the air conditioner on and off. MODE selector button Use this button to select AUTO, HEAT, DRY, COOL or FAN mode. (AUTO) : When this setting is selected, the air conditioner calculates the difference between the thermostat setting and the room temperature and automatically switches to the ‘‘COOL’’...
  • Page 21: Operation With The Remote Control Unit

    OPERATION WITH THE REMOTE CONTROL UNIT 1. Automatic Operation 2. Manual Operation (only for COOL/DRY/HEAT Model) This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the temperature setting. STEP 2 STEP 3 STEP 4 STEP 1...
  • Page 22: Adjusting The Fan Speed

    3. Adjusting the Fan Speed A. In Cooling and DRY Mode: ( A. Automatic fan speed When the night setback mode is selected, the air conditioner Simply set the FAN SPEED selector button to the automatically raises the temperature setting 2 °F when 30 minutes have passed after the selection was made, and then another 2 °F position.

This manual is also suitable for:

Xs1872

Table of Contents