T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT

Mounting Thermostat To Wallplate

1. Slide SYSTEM switch to the Off position.
2. Engage the tabs at the top of the thermostat and
wallplate.
3. Swing down the thermostat and press the lower
edge of the thermostat onto the wallplate to latch.
See Fig. 6.
A
ENGAGE TABS AT TOP OF THERMOSTAT
WITH SLOTS ON MOUNTING PLATE.
B
PRESS LOWER EDGE OF
CASE TO LATCH.
Fig. 6. Mounting thermostat to wallplate.

INSTALLER SETUP

°
°
Setting
F/
C Indication and Heat Cycle Rate
The following instructions provide the information neces-
sary to change the heating cycle rate to match the heating
equipment and to choose either Fahrenheit (°F) or Celsius
(°C) display.
69-1435–1
DASHED LINES INDICATE TABS
ON BACK OF THERMOSTAT
H o l d
S e l e
c t
M14699
NOTE: All four steps must be completed to save
changes to the °F/°C indication and the heat
cycle rate.
1. Enter Installer Setup.
Use ▲ or ▼ keys
a.
to set the tempera-
ture setpoint to 52
°F (11°C).
b.
Press the ▲ and ▼ keys simultaneously for
more than two seconds to enter installer
setup.
c.
When released the
three-digit
software revision
code displayed.
d.
Press the ▲ key.
Factory configura-
tion (FC) is
displayed
(A typical example
is shown, but
information
displayed varies
by model. This information is for factory use
only).
Optional System Checkout
When in steps 1c and 1d only, pressing the ▼ key can be
used to turn heat or cool outputs on and off. Change the
SYSTEM switch setting to test heat or cool outputs. During
testing, the 5 minute minimum off time is bypassed. No
action takes place If the system switch is in the Off
position.
Examples: System setting at HEAT: If heat is on,
pressing the ▼ key turns it off; if heat is off,
pressing the ▼ key turns it on.
System setting at COOL: If cool is on,
pressing the ▼ key turns it off; if cool is off,
pressing the ▼ key turns it on.
NOTE: In installer setup only, each press of the ▲ key
momentarily displays 1. Each press of the ▼ key
momentarily displays 2. When the keys are
released, these one-digit codes are no longer
displayed.
2. Setting °C or °F.
Press the ▲ key
a.
again to display
the current setting.
Press the ▼ key to
b.
change the °C or
°F indication.