Installer Menu Settings; Installer Menu Settings Access; Thermostat Confi Guration; System Confi Guration - ClimateMaster ATC32U01 iGate Installation Manual

Communicating, programmable thermostat
Hide thumbs Also See for ATC32U01 iGate:
Table of Contents

Advertisement

AT C 3 2 U 0 1 C o m m u n i c a t i n g , P r o g r a m m a b l e T h e r m o s t a t - I O M
R e v. : 4 F e b . , 2 0 1 3

2.0 Installer Menu Settings

2.1

INSTALLER MENU SETTINGS ACCESS

The Installer Settings can be accessed at any time from the
Main Operating screen by holding the up/down arrows simul-
taneously for 5 seconds while the thermostat is in OFF Mode.
Installer Menu Settings Overview
Thermostat Confi guration
System Confi guration
Airfl ow Selection

Option Selection

Unit Confi guration
Pump Confi guration
Valve Confi guration
Accessory Confi guration
Air Filter
Humidifi er
UV Lamp
Air Cleaner
Input Dealer Information
Humidity Confi guration
Temperature Algorithm
Demand Reduction Confi guration
Service Mode
Manual Operation
Control Diagnostics
Dipswitch Confi guration
Fault History
Clear Fault History
Restore Defaults
2.2
THERMOSTAT CONFIGURATION
Upon initial power up, the communicating thermostat will
prompt the installer for the thermostat confi guration settings.
Model number and software version of thermostat and
software version of connected DXM2 are also displayed on
this screen.
INSTALLER SETTINGS
THERMOSTAT CONFIG
SYSTEM CONFIG
ACCESSORY CONFIG
INPUT DEALER INFO
HUMIDITY CONFIG
TEMPERATURE CONTROL
DEMAND REDUCTION CNFG
SERVICE MODE
RESTORY DEFAULTS
DXM2
ATC32U01
SELECT OPTION
PREVIOUS
6
2.2.1
Adjust the staging option using the up/down arrow buttons.
Press the center button to save changes.
SINGLE STAGE
MULTI STAGE
SELECT OPTION
PREVIOUS
2.2.2
Adjust the Auxiliary Heat options using the up/down arrow
buttons. Press the center button to save changes.
ELECTRIC
MULTI FUEL
NO AUXILIARY HEAT
SELECT OPTION
PREVIOUS
AUXILIARY HEAT TO
SUPPLEMENT HEAT PUMP
AUXILIARY HEAT FOR
EMERGENCY HEAT ONLY
1.0
C 2.1
SELECT OPTION
PREVIOUS
G e o t h e r m a l H e a t P u m p S y s t e m s
STAGING
Single Stage – for control of a single stage
compressor applications
Multi-Stage (default) – for control of multi-
stage compressor applications
THERMOSTAT
CONFIGURATION
AUXILIARY HEAT
Electric (default) – for control of a system with
electric auxiliary heat
Multi-Fuel – for control of a system with furnace
for auxiliary heat
No Auxiliary Heat – for control of a system with no
auxiliary heat
THERMOSTAT
CONFIGURATION
2.2.2.1 AUXILIARY HEAT CONFIGURATION
Select Electric Auxiliary Heat mode
Auxiliary Heat to Supplement Pump
Auxiliary Heat for Emergency Heat Only
THERMOSTAT
CONFIGURATION
SAVE
SAVE
SAVE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents