SEQUENCE OF OPERATION

Turn on the Trane CleanEffects
leasing the POWER button. The backlit POWER and
RESET button will illuminate along with the first green
LED indicating power is present. When the indoor fan is
operating the first green LED will slowly flash. This indi-
cates the FIELD CHARGER and COLLECTION CELLS
have power and the unit is operating normally. There is
a slight time delay between the indoor fan starting and
LED flashing.
NOTE: There is a 10 [12] minute delay after the indoor
fan operates, before the air cleaner starts to operate,
each time the power to the air cleaner is turned off/on.
Your air filtration system only operates when the air
is circulating through the indoor unit. The air filtration
system is most effective at cleaning the air if the
fan operates continuously. Most thermostats have
a setting that will permit continuous fan operation.
Continuous fan mode during Cooling operation
may not be appropriate in humid climates. If the
indoor air exceeds 60% relative humidity or simply
feels uncomfortably humid, it is recommended
that the fan only be used in the AUTO mode.
In normal operation, the whole house air cleaner may
make a slight sound as the air passes through it and
is cleaned. In some applications, you may notice this
sound coming from the return air vent(s). If desired, this
sound level can be reduced with minimal impact on air
cleaning efficiency by reducing the power setting of the
FIELD CHARGER in the SET-UP mode (see pages
9-10).
4
by pressing and re-
TM
Numbers in [brackets] are for 50 Hz international systems.

MAINTENANCE

WARNING
L
!
RISK OF ELECTRIC SHOCK: These servicing
instructions are for use by qualified personnel
only. To reduce the risk of electric shock, do not
perform any servicing other than that contained
in this User's Information Guide unless you are
qualified to do so.
CAUTION
L
!
Before cleaning the coil or ducts in the air handler
or furnace, remove the COLLECTION CELLS, FIELD
CHARGER, and PRE-FILTER from the air cleaner.
Chemicals used during the cleaning of the air
handler, furnace, or ductwork can damage the air
cleaner components and degrade the performance
of the air cleaner.
Flashing red light indicates
that it is time to clean the
COLLECTION CELLS
CLEAN
Red light indicates that it is
PRE-FILTER
time to clean the PRE-
PRE-FILTER
FILTER
RESET
NOTE: In a communicating system, the comfort control
can be programmed to indicate when it is time to clean
the filters.
For maximum efficiency, the COLLECTION CELLS
and PRE-FILTER should be inspected and cleaned as
prescribed in this User's Information Guide.
The FIELD CHARGER should only be removed and
cleaned annually by a qualified service professional.
32-5038-10