INSTALLING THE GAS LINE
STEP 5 : Seal hole around gas line
on refractory wall
with cement or any other non-combustible
IMPORTANT: Install the gas line before finishing the
material. (Figure 33).
fireplace. If desired,
a
decorative gas appliance may be
installed. Use only iron pipe,
112"
size, and appropriate
STEP 6: Finish installation by either capping the gas
fittings. When installing gas line, a valve designed for
line or attaching a gas
log,
installation outside the fireplace is required (Figure 31).
CAUTION:
WHEN USING THE DECORATIVE
The unit is shipped from Ihe factory ready for installa-
tion. The gas line may be installed to enter the fireplace
from either side. Refer lo Figure 5 for hole location.
The gas line is intended for connection to a decorative
gas appliance incorporating an automatic shutoff device
and complying with the Standard for Decorative Gas
Appliances for Installation in Vented Fireplaces, ANSl
221.60 Decorative
gas appliance should be installed in
accordance with the National Fuel Gas C d e .
ANSl
2223.1. and NFPA 54.
BEFORE DOING ANYTHING, MAKE SURE
THE
GAS
VALVE LOCATED OUTSIDE YOUR FIREPUCE IS
SHUT
OFF.
STEP
1:
Remove gas line cover. Save screws.
Re-
move insulation from inside gas conduit
sleeve. Save insulation.
t
SLEEVE
,
SCREWS
SIDE
-GAS
LINE
STEP
2: With
gas
line
conduit sleeve in place strike the
back of the refractory using a light punch.
STEP 3: Install
a 7 inch
minimum nipple to reach
inside
the fireplace. Allow enough thread to install
cap (or
elbow
if continuing installation).
STEP 4: Repack insulation into conduit sleeve all
around nipple. Replace screws. (Figure 32),
APPLIANCE
THE
FIREPLACE DAMPER MUST
BE
SET IN THE FULLY
OPEN
POSITION.
THIS INSTALLATION
I S
NOT LISTED BY
UNDERWRITERS LABORATORIES, INC,"
RADCO LAB. in accordance
wIth ICBO require-
ments
and
is
approved for use with this fireplace
model.
INSTALLATION OF GAS
LOG LIGHTER
IF YOUR FIREPLACE
I S
PROVIDED WITH
A
GAS
LINE FOR ATTACHMENT TO
A
GAS LOG LIGHTER,
PLEASE FOLLOW THESE INSTRUCTIONS CARE-
FULLY.
1)
BEFORE
DOING ANYTHING, MAKE SURE THE
GAS VALVE LOCATED OUTSIDE YOUR FIRE-
PLACE
IS SHUT OFF.
2) REMOVE THE CAP AT END OF GAS PIPELINE
PROTRUDING FROM SlDE OF THE REFRAC-
TORY. (SEE FIG. 33).
3) CONNECT
FITTINGS:
TWO
-
112
INCH DIA. 45" ELBOW
ONE
-
1 1 2
INCH DIA. CLOSE NIPPLE
4 )
INSTALL GAS LOG LIGHTER MAX.
24'
LONG.
1/2
INCH DIAMETER TO ELBOW. (SEE
FlG.33)
GAS
LOG LIGHTER MUST BE INSTALLED FLUSH
TO
M E HEARTH FLOOR OF YOUR APPLIANCE. DO
NOT ELEVATE GAS LOG LIGHTER.
YOUR GAS LOG LIGHTER IS NOW READY
FOR
USE.