Circulation Air Blower Data (*9Mpv) - International comfort products *9MPT050F12C1 Technical Support Manual

Four position
Table of Contents

Advertisement

Circulation Air Blower Data - *9MPV050
Cooling Adjustment
DIP Switch
High Cool @ .50
(OFF = 0 and
in wc(125 Pa)
ON = 1)
5 & 6
CFM
00
1246
*00
1211
00
1122
01
1105
01
1027
01
945
10
892
10
820
10
745
11
688
11
609
11
541
Airflow performance includes 1" washable filter media.
*Factory Setting
**Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating
Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is
present with the "O" line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable.
Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls.
Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise).
Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory
default settings.
Table 2
DIP Switch
0.10 in wc (25 Pa) ESP
(OFF = 0 and ON = 1)
1 & 2
*00
01
10
11
* Factory Setting
Table 4
DIP SW2 - - 7/8
(OFF = 0 and ON = 1)
*00
01
10
11
Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1
Airflow resumes to 100% after on delay time is completed
Airflow stops (or switches to continuous fan speed) after off delay time is completed
* Factory Setting
MAX CFM (L/s) for Factory Washable Filters
Filter Size (in/mm)
14" X 25" (356 x 635)
16" X 25" (406 x 635)
20" X 25" (508 x 635)
24" X 25" (610 x 635)
Max CFM (L/s) based on 600 FPM (3.0 m/s)
440 04 2024 01
Low Cool (80%
of High Cool)
L/s
CFM
L/s
588
997
471
571
969
457
529
898
424
521
884
417
485
822
388
446
756
357
421
714
337
387
656
310
352
596
281
325
550
260
287
487
230
255
433
204
Airflow
Continuous Fan @
CFM
L/s
592
279
1021
482
1346
635
1346
635
Cooling Delay Options (SW2 - - 7, 8)
ON DELAY
Airflow during on
Timed ON (sec)
5
5
30
30
CFM
L/s
1400
661
1600
755
2000
944
2500
1180
Specifications are subject to change without notice.
Heating Rise Adjustment
DIP Switch
** Adjust
(OFF = 0 and
Jumper
ON = 1)
Setting
3 & 4
+
00
*NOM
*00
00
- -
01
+
NOM
01
- -
01
10
+
NOM
10
10
- -
+
11
NOM
11
- -
11
Table 3
DIP Switch
1 & 2
3 & 4
5 & 6
7 & 8
Timer OFF (sec)
delay
OFF
90
OFF
0
50%
30
50%
180
NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s).
These filters only allow half the airflow when compared to 600 FPM
(3.0 m/s) filters.
High Heat
Low Heat
Rise
Rise
Change @
Change at
0.20 in wc
Resultant
(50 Pa)
Static
- -4
--3
0
0
5
5
3
4
7
7
13
14
--1
0
4
5
9
9
--15
--15
--13
--12
--9
--9
SW2 DIP Assignments
Blower Parameter
Cont Fan Adj
Heat Speed Adj
Cool Speed Adj
Cool On/Off Delay
OFF DELAY
Airflow during off
delay
100%
OFF
100%
50%