Servicing the Actuator
FOR MODELS: 7050, 7205, 7257, 7293, 7337, 7342, 7344, 7376, and 7388
1. First, run the actuator rod all the way out
or until the motor bogs down. Remove the
1/8" brass socket filler plug with a 3/16" hex
key wrench.
2. Next, with the same wrench, remove the
1/8" level plug.
3. Run the unit until the actuator rod is
completely retracted. Let all the fluid
run out until it stops.
4. Next, start pouring your fluid in through
the filler hole, at the same time run the
actuator until the rod is completely
extended. You can use #2216 Mystic or
equivalent, SAE 20 or 30 nondetergent
oil, or Dextron transmission fluid.
5. Keep fluids running out level hole,
while running actuator rod back up.
Stop at 3" before completely retracted.
6. Next, replace your level plug.
7. Then, run unit until actuator rod is
completely extended and replace your filler
plug.
13