PC9155 Wireless Alarm System
[328] Miscellaneous Alarm Reporting Codes
Duress Alarm
This reporting code is transmitted whenever a Duress code is used to perform any function on the system. The reporting code is sent to the Alarm & Restore call
direction group.
Opening After Alarm
This reporting code is transmitted when the system is disarmed after an alarm; if an alarm occurred during the previous armed period. The reporting code is sent to
the Alarm & Restore call direction group.
Recent Closing
A Recent Closing transmission is transmitted if an alarm occurs within 2 minutes of the exit delay time expiry. The Recent Closing report is transmitted for the first
alarm only. The reporting code is sent to the Alarm & Restore call direction group. Also, the Recent Closing event is transmitted, even if the zone alarm has trans-
mission delay enabled.
Cross Zone/Police Code Alarm
When using Cross Zoning (section [016] option [1] ON), this reporting code is sent when two 'crossed' zones go into alarm during the Cross Zone period. When
using Police Code (section [016] option [1] OFF), this reporting code is sent when any two zones go into alarm. In both cases, only one reporting code is sent during
each armed-to-armed period. The reporting code is sent to the Alarm & Restore call direction group.
Burglary Not Verified
When using Cross Zoning (section [016] option [1] ON), this reporting code is sent if the Cross Zone timer is initiated by the first cross zone alarm, but it is not ver-
ified by a second cross zone alarm before the timer expires. This reporting code is sent to the Alarm & Restore call direction group.
Alarm Cancelled
If an alarm event is sent after transmission delay has expired, then a cancel window time will start. Any time during this window if a valid access code is entered
then this event is logged and transmitted. When this reporting code/event has been acknowledged by the central station a keypad will ring back. This reporting code
is sent to the Alarm & Restore call direction group. See section [377] Communications Cancel Window.
[329] Priority Alarm and Restore Reporting Codes
(Fire, Auxiliary, Panic Alarms/Restores and Fail to Report In)
If enabled and used to generate manual alarms, these reporting codes are sent to the Alarm & Restore Call Direction group.
[330]-[336] Zone Tampers & Tamper Restorals
These reporting codes are used by the communicator to transmit zone tampers and restores for zones 1 to 34.These reporting codes are sent to the Tamper Alarm &
Tamper Restore call direction group of the system.
[338] Miscellaneous Tamper Reporting Codes
System Tamper & Restore
These reporting codes are sent to the system Tamper Alarm & Tamper Restore call direction group when a panel tamper occurs.
Keypad Lockout
Whenever the system enters keypad lockout, this reporting code is sent to the system Tamper Alarm & Tamper Restore call direction group.
[339] Closing/Reporting Codes (Closing by Users 1-16)
When the system is armed, a closing reporting code is transmitted for the user code used to arm the system after the exit delay expires. These reporting codes are
sent to the Opening & Closing call direction group of the system. In addition, either "Armed in Stay Mode" or "Armed in Away Mode" is logged to the event buffer.
Closing by Users (Duress)
When the system is armed by an access code programmed as duress, the corresponding closing reporting code is transmitted. This reporting code is sent to the
Opening & Closing call direction group.
[341] Miscellaneous Closing (Arming) Reporting Codes
Closing By Access Code 40
See [339] Closing by Users 1-16
Automatic Zone Bypassing
This stops transmission of zone bypass information for systems set up for an automatic communication format (SIA and Contact ID). Enter [00] to disable the auto-
matic zone bypassing communications. If the zones are to be identified, they are transmitted with the Partial Closing to the Opening & Closing call direction group.
(24 Hour zone types will transmit that they have been bypassed when the user exits the bypassing menu).
Partial Closing
If zones were manually bypassed at the time of arming, this reporting code is transmitted to the central station with the Closing code to warn of a security compro-
mise. Automatic bypasses caused by Stay arming will not cause this code to be transmitted. Zones force armed by automatic arming will transmit in the manner
described above. If SIA is used, each zone will be identified using the UB-XX (un-typed bypass) identifier. The identified zones will follow the partial closing code
and precede the closing transmission. This reporting code is sent to the Opening & Closing call direction group.
Special Closing
][
If the system is armed without an access code using Keyswitch Zone, Downloading, Quick Arm [
0], or Stay or Away function keys this reporting code is trans-
mitted. In addition, either "Armed in Stay Mode" or "Armed in Away Mode" is logged to the event buffer for all closing types. This reporting code is sent to the
Opening & Closing call direction group.