connection & installation
COMMUNICATION PROTOCOL DIP SWITCH SETTINGS
Coaxial communication automatically detects signals, and so does not require a separate communication
setup process.
Pin No.
1 ~ 4
5
6
7
8
9
10
Protocol Settings
Select a communication protocol for the camera.
No
Protocol
1
SAMSUNG-T
2
SAMSUNG-E
3
Pelco-D
4
Pelco-P
5
Panasonic
6
Vicon
7
Honeywell
8
AD
8
GE
10
Bosch
connection & installation
18_
Transfer Method (RS-485/422) Settings
#4
#3
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
Purpose
Protocol Settings
Response Mode Settings
Terminal Resistance TX
Terminal Resistance RX
TEST
Factory Default
#2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
#1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON