10.6. Replacement of FC Multiflow
Cover
1. Remove 4 caps and unscrew the 4 screws shown at the
picture.
2. Then pull first part of multiflow cover slightly from the top.
3. Then remove the one screw.
4. Then pull second part of multiflow cover slightly from the
bottom and rotate to the left side
(In case of icing between cover and evaporator, do not
pull the cover with full force, slightly shake the cover to
brake the icing then pull.)
38