Troubleshooting - Husqvarna 1365GN Operator's Manual

Husqvarna 1365gn portable generator operator's manual
Hide thumbs Also See for 1365GN:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

Problem
Engine is running, but no AC
output is available.
Engine runs good at no-load but
"bogs down" when loads are
connected.
Engine will not start; or starts
and runs rough.
Engine shuts down when
running.
Engine lacks power.
20
Cause
1. One of the circuit breakers is open.
2. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
1. Fuel Valve is in "Off" position.
2. Out of fuel.
3. Stale fuel.
4. Water in fuel.
Out of fuel.
Load is too high.
Correction
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in good
condition.
1. Disconnect shorted electrical load.
2. See Don't Overload Generator in
Operation section.
3. Contact authorized service facility.
1. Turn fuel valve to "Open" position.
2. Fill fuel tank.
3. Drain fuel tank and carburetor; fill with
fresh fuel.
4. Drain fuel tank and carburetor; fill with
fresh fuel.
Fill fuel tank.
See Don't Overload Generator in Operation
section.
www.usa.husqvarna.com

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents