Electrolux DF36 Service Manual page 28

Module i
Hide thumbs Also See for DF36:
Table of Contents

Advertisement

! Gutter Resistance
!
! !
!
In the multi-way connector, located in the refrigerator top flow, it is possible to measure the ohmic resistance the
tension of the current being fed to the gutter resistance.
1. In the refrigerator top flow male connector, measure the value of the ohmic resistance of the gutter resistance
positioning the probing needles of the multimeter, already set to the resistance scale, on the terminals 5-6.
OHMIC RESISTANCE OF THE
GUTTER RESISTANCE AT +23ºC
1
6
TOP FLOW MULTI-WAYS MALE
CONNECTOR
2. In the top flow female connector, next to the cabinet, it will be possible to measure the alternate tension (127V
or 220V) of the current being fed to the gutter resistance on terminals 5-6, while the product is defrosting.
1.4.4 Checking the thermal fuse and the defrost thermostat
With the digital multimeter adjusted to the continuity scale, check the thermal fuse and bimetal thermostat
connector for the following points:
2
4
3
1
This document cannot be reproduced or passed to third parties without authorization of Electrolux do Brasil S.A..
2
3
5
4
1
2
6
5
TOP FLOW MULTI-WAYS
FEMALE CONNECTOR
IN TERMINALS 2-4 THERE SHOULD BE CONTINUITY TO
GUARANTEE THE PROPER OPERATION OF THE THERMAL FUSE.
THERE SHOULD BE CONTINUITY BETWEEN TERMINALS 1-3 IF THE
TEMPERATURE IN THE BIMETAL DEFROST THERMOSTAT IS BELOW
-6°C WITH A VARIATION OF ±4°C.
THERE WON'T BE CONTINUITY BETWEEN TERMINALS 1-3 IF THE
TEMPERATURE IN THE BIMETAL DEFROST THERMOSTAT IS ABOVE
+25°C WITH A VARIATION OF ±3°C.
FOR 127V
FOR 220V
1094 to 1210
3284 to 3630
3
4
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents