8.4.2.

Service Maintenance

8.4.2.1.
Maintenance Cycle
The following table shows the service cycle of the main parts.
Item
Fuser Unit
Transfer Roller
Retard Pad Assembly
1
*
Average life is based on an average of 5% coverage of the printable area and standard density when the recommended media
is used ( refer to Example: 5% coverage ). The life of a toner cartridge is varied dependingon the coverage, temperature, humidity
or media etc. So the average life cannot be assured. Continuously printing 10% coverage of the printable area will reduce the life
of the toner to about half as compared to printing 5% coverage.
8.4.2.2.
Lubrication
Lubricate the following parts when they are replaced or cleaned :
Fuser Unit
Main Chassis
8.4.2.3.
Recommended Lubrication
Lubricate the following parts when they are replaced or cleaned :
8.4.3.

Counter Reset

You are able to reset the counter of the following items, when they are replaced.
Item
OPC Drum Unit
Press the CONTINUE button more than 20 seconds. (The error indicator will go off.)
(KX-PDM7)
Average Life
90,000 pages *1
90,000 pages *1
90,000 pages
Part
Drive Gear, Intermediate Gear, Gear shaft
Drive Gear, Gear Shaft
Part Number
PJOL-HP500
GL-YM-103
PJOL-GE676
PJOL-948P
Service (x 1000 pages)
18
36
54
R: Replace (Service Man Replaceable)
Lubrication Point
Refer to the part list for locations.
Name
Main Part
Grease
Drive Gear
Grease
OPC Gear
Fuser Gear
Grease
Feed Roller
Oil
Roller Shaft
Counter Reset
97
72
90
108
R
R
R
KX-P7100