• COOLING ONLY
Model No.: LT-D4881FJ/FH
INDOOR WIRING DIAGRAM
BR
YL
FUSE T3.15A
BR
BL
RD
GN/YL
TERMINAL
BLOCK
INDOOR
DRAIN
STEP
MOTOR
PUMP
MOTOR
THERMISTOR
FLOAT S/W
CN - DISP
OPTION
RD
DISPLAY PCB
BK
3854AP20072J
OUTDOOR WIRING DIAGRAM
PIPE
TM
R
S T N
POWER SUPPLY
REMOTE
CONTROL
–17–
F1
BK
BK
WH
RD
F1
WH
OR
WH
BK
1
3
5
31
52C
CRANK-CASE
A
HEATER
B
2
4
6
32
BK
OR
BR
BR
Co
Co
BK
RD
WH
YL
BK
YL
BK
OR
OR
BL
FMo
FMo
49FMo
49FMo
T3 T2
T1
CM
REMOVE JUMP WIRE
WHEN CONNECTING
FIRE ALARM SYSTEM
BK
BK
1
WH
2
3
BK
4
5
6
7
WH
BK
8
9
1(L)
2(N)
3
4
5
TMo
GN/YL
3854A20078C