Sony KDL-40SL150 Service Manual page 12

Lcd digital color television
Hide thumbs Also See for KDL-40SL150:
Table of Contents

Advertisement

LED Indicators
Diagnostic Item
Description
Main Power
TCON Error
Viewing the Self Check Diagnostic List
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second
of each other:
Channel 5
DISPLAY
The Self Check list displays.
NOTE: This is the same as accessing Service Adjustments.
The
logo displays momentarily, then the Service Mode list
displays.
Service/ADC Auto Calibration
Version: ER2.6-C121 DTT: S255.P033.S077
Model: 40SL150
Serial : 8000016
Power on Time: 00000H
Diagnostic and Serial Update
ADC Auto Calibration
Clone User Setting
Direct Log to USB
Factory Default
Change
RETURN
KDL-40SL150
Number of times
STANDBY lamp flashes
2 times
DC Alert1
3 times
4 times
HDMI
5 times
Backlight
6 times
Temp
7 times
HFR Error
8 times
Volume +
TV POWER .
Back
Exit
Possible Location
Power Supply (IP1 Board)
BM3 (Main) Board
Power Supply (IP1 Board)
LCD Panel
BM3 (Main) Board
LCD Panel
BM3 (Main) Board
LCD Panel
3. To display the Self Diagnostic list, press
Service Mode/Product Information
Version: ER2.6-C121 DTT: S255.P033.S077
Model: 40SL150
Power on Time: 00000H
Serial : 8000016
Diagnostic Information
2-MAIN POWER:
3-DC ALERT1:
4-TCON:
5-HDMI:
6-Backlight:
7-TEMP:
8-HFR:
101-WDT:
Change
RETURN
4. To exit Service Mode, press
KDL-40SL150
.
1
1 indicates an error was detected
0 indicates no error was detected
0
0
0
0
0
0
0
Back
Exit
.
12

Advertisement

Table of Contents
loading

Table of Contents