Power Supply CBA Bottom View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
J116
GND
J114
GND
J124
GND
J103
GND
4A 125V
R1003
Q653
J120
D1002
GND
VCC J117
C650
D650
C654
C655
J113
P-ON+21V
Q656
D662
J104
AMP+13V
J102
GND
22
23
CAUTION ! :
For continued protection against risk of fire,
replace only with same type 4A, 125V fuse.
ATTENTION : Utiliser un fusible de rechange de même type de 4A, 125V.
BA21N0F0102 1
F601 4A/125V
D660
FH602
J601
GND
C602
T601
J602
GND
Q601
C603
J122
GND
J121
GND
CN631
2
BC602
1
10-21
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
FH601
R601
SA601
GND
J603
Q602
R611
D608
D607
BC603
C605
BA21N0F01021