  • Page 4 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Page 5: Table Of Contents

    CONTENTS REFERENCES ............... v Conventions..............v Reference Documentation ..........v Service, Support and Warranty ........v SAFETY REGULATIONS ..........vi General Safety Rules............. vi Laser Safety ..............vii Radio Compliance ............xi FCC Compliance ............xii GENERAL VIEW ............xiii INTRODUCTION ............1 Terminal Description ............
  • Page 6 GLOSSARY..............29 INDEX ................31...
  • Page 7: References

    For further details refer to the Manuals of the various programs provided when downloading the EasyGen™ Demo Version. SERVICE, SUPPORT AND WARRANTY Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com/services/support and click on the links indicated for further information including: Services –...
  • Page 8: Safety Regulations

    Do not attempt to disassemble the F725-E series terminal, as it does not contain parts that can be repaired by the user. Any tampering will invalidate the warranty.
  • Page 9: Laser Safety

    F725-E Laser beam output window Manufactured: Jan 2001 Datalogic S.p.A. – Calderara di Reno (BO) - Italy This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device...
  • Page 10 F725-E/RF Laser beam output window LASER LIGHT AVOID EXPOSURE LASER LIGHT DO NOT STARE INTO BEAM IS EMITTED FROM CLASS 2 LASER PRODUCT THIS APERTURE MAX. OUTPUT RADIATION 1.0 mW EMITTED WAVE LENGTH 630 ~ 680 nm EN60825-1:2001 CAUTION – CLASS 2 LASER LIGHT This product complies with 21 CFR Subchapter J WHEN OPEN DO NOT STARE INTO BEAM Figure 2 - F725-E/RF Laser Safety Labels...
  • Page 11 ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your terminal. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
  • Page 12 DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs-arbeiten zu öffnen.
  • Page 13: Radio Compliance

    ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1.
  • Page 14: Fcc Compliance

    FRANÇAIS Contactez l'autorité compétente en la gestion des appareils à radio fréquence de votre pays pour vérifier la nécessité du permis d'usage. Pour tout renseignement vous pouvez vous adresser au site web: http://europa.eu.int/comm/enterprise/rtte/spectr.htm. DEUTSCH Um die Notwendigkeit der Verwendungslizenz zu prüfen, wenden Sie sich an die Behörde, die auf der Radiofrequenzgerätsführung Ihres Lands bewandert ist.
  • Page 15: General View

    GENERAL VIEW Figure 3 - F725-E Series Terminals Overview Key: Cradle communications window Multi-function LED Reset key (protected) Laser beam output window xiii...
  • Page 17: Introduction

    INTRODUCTION INTRODUCTION TERMINAL DESCRIPTION Two different models of this terminal are provided: communicates with the host computer via a Formula 725-E: cradle connection; Formula 725-E/RF: communicates with the host computer via radio frequency or normal cradle connection. 1.1.1 F725-E The F725-E Hand-Held Laser Terminal offers features and functionality typical of high-end product.
  • Page 18: F725-E/Rf

    The F725-E/RF terminal is a lightweight, compact-sized and fully programmable radio frequency terminal 100% compatible with the Datalogic STAR-System™, the RF narrow band solution for mobile applications. It solves the most complex application needs, exploits the "overspeed" feature to boost software performance, and has 512 KB of RAM memory for managing large databases and 512 KB of Flash memory for application programs of large dimensions.
  • Page 19 Multi-function LED Reset key (protected) Laser beam output window The F725-E series terminals have a backlit LCD graphic display of 16 characters by 4 lines plus a line in the upper part of the display for the programmable icons: The icons which can...
  • Page 20: Application Development Programs

    MS-DOS environment and developed specifically for the type of terminal processor. The libraries, developed by Datalogic, permit direct management of the terminal functions. For example, the management of barcode reading devices is immediate and rational thanks to interaction with functions that automatically start up the barcode acquisition procedure.
  • Page 21: Downloading Easygen™ Demo

    INTRODUCTION DOWNLOADING EASYGEN™ DEMO By logging on to www.datalogic.com/services/support and clicking on the Products>Portable Data Collection Terminals link, you can download for free the EasyGen™ Demo Software package containing the following items: • EasyGen™ Demo Version (user-friendly and highly productive application generator) •...
  • Page 22: Accessories

    F725-E SERIES TERMINALS ACCESSORIES F925 – F925 Dark Transceiver/Charger - RS232/RS485 F925/4 Transceiver/Charger - 4 slots - RS232(x1)/RS485(x4) F902 T-Box RS485 Network/PC connection kit Functional Case – order number 94ACC1267 FBK725-E Battery kit NiMh 725-E FBS725-E Battery kit NiMh F725-E (5 pcs pack)
  • Page 23: Connections

    CONNECTIONS CONNECTIONS CRADLE To make the F725-E series terminal operative, it is necessary to insert it into the Formula 925 Transceiver Charger cradle or into the Formula 925/4 Multi Transceiver Charger which has been previously connected to the power supply and to a host computer with an available RS232, RS485 or Eavesdrop line.
  • Page 24: Connection To The Host Computer

    F725-E SERIES TERMINALS CONNECTION TO THE HOST COMPUTER Before proceeding with this phase, make sure that both the computer and the terminal are switched off. CAUTION 2.2.1 RS232 Connection To connect the F925 cradle to the host computer, proceed as indicated below: Connect the cable to the serial port of the host computer.
  • Page 25 CONNECTIONS Figure 8 - RS232 Multi Cradle Connection Key: Host computer Serial cable Multi-cradle F925/4 Power supply The RS232 connection allows transmission between the host computer and the first station of the multi-cradle. For this reason, it is necessary to insert an RS232/RS485 converter between the host and the cradle to enable transmission with NOTE all the four stations.
  • Page 26: Connection With Eavesdrop Interface

    F725-E SERIES TERMINALS 2.2.2 Connection with Eavesdrop Interface The cable Kit 94A054030 provides two cables; one for Eavesdrop connections and one for Modem connections. The Eavesdrop connection enables the F725-E terminal to be connected to an existing asynchronous RS232 line (for example between the host computer and video terminal).
  • Page 27: Rs485 Connection

    CONNECTIONS 2.2.3 RS485 Connection The RS485 line allows connecting several terminals to a single RS232 line by means of a network (see the "Formula 904/N User Manual). If the network is made using the Formula 902 T-Box, the line can be extended up to 1200 meters and up to 32 different types of Formula cradles can be connected.
  • Page 28 F725-E SERIES TERMINALS Figure 10 - RS485 Connection Key: Host computer Formula 902 T-box Formula 904/N Interconverter Single cradle F925 Multi cradle F925/4 Power supply...
  • Page 29: Rf Connection

    CONNECTIONS 2.2.4 RF Connection The RF connection allows the F725-E/RF terminal to communicate with the host via radio frequency using the STARGATE™ RF base station connected to the host computer. Figure 11 - RF Connection Key: Host computer Power supply Formula 725-E/RF STARGATE™...
  • Page 30: Connection Cable

    F725-E SERIES TERMINALS CONNECTION CABLE Several types of cables are provided depending on the computer and on the connection. The following cables and cable Kits are listed with their order number. RS232 Connection with PC/AT or compatible: cable 94A054000 Cradle side...
  • Page 31 CONNECTIONS The black flat cable allowing the Modem connection has the following pinout: Modem Cable DB25 side Cradle side 25-pin D-sub RJ45 (male) TO MODEM CONNECTIONS RS485 Connection: cable 94A054020 Twisted Pair RX/TX RX/TX...
  • Page 32: Use And Operation

    The Demo Version of EasyGen™ can be downloaded free of charge from the Datalogic web site together with 5 ready-to-use example applications in 5 different languages. Refer to chapter 6 of the EasyGen™ User's Manual for details.
  • Page 33 USE AND OPERATION ARROW KEYS: activate display scroll in the direction indicated by the arrow when the function is assigned by the application program. Function activates the "Select" mode and only in this mode you can use F6, F7 and F8 functions: <SHIFT><SHIFT><Up Arrow>...
  • Page 34 F725-E SERIES TERMINALS NUMERIC ALPHANUMERIC KEYS: allow the entry and display of the main numeric symbol. If the <SHIFT> has first been pressed, the choice alternative alphabetic characters will be activated. BACKSPACE KEY: deletes the last character entered. SPACE KEY: allows the introduction of a blank space.
  • Page 35: Barcode Scanning

    The beam emitted by the laser must completely cover the barcode; the LED (and the acoustic signal, if activated) will indicate if the scan was carried out correctly. Figure 12 - F725-E Series Terminal Scanning a Barcode Throughout the operation of the application, the battery icon...
  • Page 36: Deleting The Application Program

    F725-E SERIES TERMINALS DELETING THE APPLICATION PROGRAM This procedure allows deleting application programs developed with DS for Formula™. If you want to delete programs provided or developed by EasyGen™, refer to chapter 6 of the EasyGen™ manual. The following procedure causes data to be deleted even if not completed.
  • Page 37: Downloading Data To Host

    USE AND OPERATION DOWNLOADING DATA TO HOST Data can be downloaded from the terminal to the host PC in different ways, depending on the application loaded and on the terminal model. If working with F725-E (batch model), the application software allows downloading data onto the PC by simply inserting the terminal into the cradle or by direct operator intervention on the terminal or host computer.
  • Page 38: Maintenance

    CAUTION Recharge the terminal by simply inserting it into its cradle; Datalogic S.p.A. recommends a minimum uninterrupted recharging time of eight hours. When using the NiMh battery a standard recharge does not allow taking fully advantage of the improved battery technology.
  • Page 39 MAINTENANCE During the battery recharge the color of the LED positioned on the cradle changes from red to green. If using the NiCd battery pack, the LED color changes when 70-80% of the complete charge is reached. If using the NiMh battery pack, the LED color changes when 50-60% of the NOTE complete charge is reached due to the battery...
  • Page 40: Replacing The Batteries

    F725-E SERIES TERMINALS REPLACING THE BATTERIES Before proceeding, ensure that the terminal is switched off and that the data it contains has been downloaded onto the host computer. CAUTION To replace the batteries correctly, proceed as follows. Turn over terminal,...
  • Page 41: Cleaning The Terminal

    MAINTENANCE Close the battery again by fitting the cover as shown in the figure and screw shut by turning clockwise. Dispose of used batteries in accordance with the relevant laws in force. NOTE CLEANING THE TERMINAL Clean the terminal from time to time with a slightly damp cloth. Do not use alcohol, corrosive products or solvents.
  • Page 42: Troubleshooting

    F725-E SERIES TERMINALS TROUBLESHOOTING PROBLEM CAUSE REMEDY When the trigger is Flat batteries. Recharge terminal. pressed the Batteries completely Replace batteries. terminal does not flat or broken. come on. When the trigger is Flat batteries. Recharge terminal. pressed, the terminal displays...
  • Page 43: Technical Features

    TECHNICAL FEATURES TECHNICAL FEATURES Optical Features F725-E Std F725-E LR Light source Laser-scanner; VLD source; 630-680 nm Scan rate 35±5 scans/sec Minimum resolution 0.15 mm / 6 mils 0.25 mm / 9.8 mils Skew angle ± 65° ± 60° Pitch angle ±...
  • Page 44 F725-E SERIES TERMINALS Programming Features Bar codes decoded Standard 3/9 Extended 3/9 Italian pharmaceutical Interleaved 2/5 ITF 14 Industrial 2/5 Matrix 2/5 UPC - EAN UPC only UPC/EAN + Addon 2 UPC/EAN + Addon 5 UPC-E only UPC 8 only UPC-A &...
  • Page 45 GLOSSARY Barcode A pattern of variable-width bars and spaces which represents numeric or alphanumeric data in binary form. The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin.
  • Page 46 Random Access Memory. Data in RAM can be accessed in random order, and quickly written and read. This memory is volatile and therefore data is lost when power is not present. Real Time Clock. Terminal A Datalogic portable computer product.
  • Page 47 INDEX Charging the Batteries; 22 Cleaning the Terminal; 25 Replacing the Batteries; Accessories; 6 Application Development Programs; 4 Package Contents; 5 Barcode Scanning; 19 Reference Documentation; Connections; 7 Connection Cable; 14 Connection with Eavesdrop Interface; 10 Safety Regulations; vii Cradle; 7 FCC Compliance;...
  • Page 48 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el F725-X, Hand Held Laser Terminal F725-X/LR, Hand Held Laser Terminal with Laser Long Range...
  • Page 49 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el F725-E/RF 512 K, Hand Held Terminal F725-E/LR/RF 512K, Hand Held Terminal e tutti i suoi modelli and all its models et tous ses modèles...