....................................................................... 4
2-1. General ..................................................................... 5
3-2. Connector ................................................................. 7
3-6. Main Board ............................................................... 9
3-9. Holder Assy ............................................................ 11
1) When repairing this device with the power on, if you remove
the main board or open the upper panel assy, this device stops
working.
In this case, you can work without the device stopping by
fastening the hook of the DOOR OPEN switch (S801) with tape.
2) This set is designed to perform automatic adjustment for each
adjustment and write its value to EEPROM. Therefore, when
EEPROM (IC801) has been replaced in service, be sure to per-
form automatic adjustment and write resultant values to the new
EEPROM.
Refer to page 12 for details.
TABLE OF CONTENTS
4-1. General ................................................................... 12
6-5. Printed Wiring Board (-11) ..................................... 31
6-6. Printed Wiring Board (-12) ..................................... 34
tape
S801
- 3 -
........................... 17
................................... 54
upper panel assy
MAIN board