Orion ODC-10000 User Manual

Dvi converter
Hide thumbs Also See for ODC-10000:

Advertisement

Quick Links

DVI Converter
ORION CO.,LTD.
www.oriondisplay.net
Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea
Tel : +82-2-6678-8533,
Fax: +82-2-6678-8599
User's Manual
ODC-10000
Thank you for purchasing our DVI Converter.
Please read through this user's manual for safety before installing this product.
This product is manufactured for Multi Plasma display model only.

Advertisement

Table of Contents
loading

Summary of Contents for Orion ODC-10000

  • Page 1 DVI Converter ORION CO.,LTD. www.oriondisplay.net Address: 257-6, Gongdan-dong, Gumi-si, Gyeongsangbuk-do, Korea Tel : +82-2-6678-8533, Fax: +82-2-6678-8599 User's Manual ODC-10000 Thank you for purchasing our DVI Converter. Please read through this user's manual for safety before installing this product. This product is manufactured for Multi Plasma display model only.
  • Page 2: Table Of Contents

    6. DVI Converter Protocol ............41 7. Check followings before asking for service ....60 8. Specification ................61 DVI Converter (ODC-10000) : 1EA DVI-D Cable User's Manual : 1EA DVI Converter_Bracket : 2EA PSW M3*8 : 6EA ORION PDP CO., LTD. |...
  • Page 3: Dvi Converter Odc

    Class A digital device malfunction. It is a device designed for business purpose with a safety Warning certificate for electromagnetic interference, which user should be mindful of. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 4: Names And Functions

    Serial/Ethernet Select [CTRL SET] Displays DVI2 output information AC 100~240V 50/60Hz BNC Connector Select communication mode between Serial (RS- Power ON/OFF Switch 232C) or Ethernet (LAN) Power On/Off switch. (AC 100~240V, 50/60Hz). | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 5: Installation

    DVI Signal Distributor HDMI New MFC Controller DVI 1 Cable HD-SDI DVI 2 Cable RS-232 DVI Converter RS-232 RS-485 USB Ethernet LCD / PDP Monitor Component Video Source S-Video Control System CVBS | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 6: How To Configure Dvi Converter Control Mode

    Then the DOS window is open and ping test start. (Ping test can be done at DOS window) DVI Converter RS-232C Distributor PC (Controller) PDP 1 PDP 1 RS-232C PC (Controller) PDP 1 DVI Converter | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 7: Ip Address Setting

    Click “Get TCP/IP Info.” and check the IP address. DVI Converter RS-232C Distributor PC (Controller) PDP 1 Check whether the exact TCP/IP default values that saved in DVI Converter is loaded.. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 8 RIGHT SEL DVI 1 MENU SEL DVI 1 SEL DVI 2 MENU SEL DVI 2  CTRL SET IP SET CTRL SET IP SET DVI Converter DVI Converter DOWN DOWN | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 9 RIGHT SEL DVI 1 MENU SEL DVI 1 SEL DVI 2 MENU SEL DVI 2  CTRL SET IP SET CTRL SET IP SET DVI Converter DVI Converter DOWN DOWN | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 10: Using The Main Key Of Dvi Converter

    If the LED on ""CTRL_SET" button is turned off, it can be controlled CTRL SET IP SET as Serial (RS-232C) mode. VIDEO DOWN DVI Converter If the LED on ""CTRL_SET" button is turned on, it can be controlled DOWN as Ethernet(LAN) mode. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 11 DVI 2 LEFT RIGHT MENU Ethernet IP Setting [IP SET] SEL DVI 2 x "IP SET" button is used to do IP Setting in Ethernet mode. IP SET DVI Converter DOWN | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 12: How To Use Osd

    Display Display Move Select Exit Move Select Exit MENU MENU Move Select Exit Move Select Exit MENU MENU NTSC OSD (Video, S-Video) PAL OSD (Video, S-Video) PC OSD PIP OSD | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 13 If you select "No" or Menu to return to Initialize menu. Screen If you select "Yes" for User data initialization. Feature Feature Display Move Select Exit MENU Background : Adjustment range is from 0 to 10. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 14 PIP SWAP  Feature Output Res 853x480,60 Caution: Some devices cannot be displayed with Frame Lock mode. Frame Lock  Frame Lock  Display Display Move Select Exit MENU | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 15: How To Use Mscs

    COM1, COM17 … Click Exit from File (Ctrl+X) to end the program. Communication configuration Sub-Communication Baud Rate 115200 bps Data Bit 8 Bits Stop Bit 1 Bit Parity Bit None Parity Bit | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 16 When the connection is successfully completed after setting Com Port, following Connect : Connect the communication. Message dialog is displayed. The dialog window will be disappeared in 1 second. Set the Ethernet communication. LAN : | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 17 Select the input mode of DVI Converter. One of DVI, HDMI, HDSDI, PC, DTV, S-VIDEO, and VIDEO can be selected. Set : Select one mode from 7 Input Modes and execute. DVI Converter Main Dialog | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 18 50Hz / 60Hz Set : Set the output resolution. OSD Information „ 16:9 The DVI converter input and input resolution are displayed on the screen. 16:9(LB) 16:9(LBS) 14:9 14:9(LB) 14:9(LBS) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 19 Firmware Default : Initialize the adjusted values to the default values. Aspect Ratio, PIP Mode, Test Pattern, Key Lock, Fan Check, Firmware Version, MSCS Version information) Picture Control Dialog Status Dialog | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 20 Lock/FreeRun can be configured by the keypad of DVI converter besides MSCS. While Menu OSD is not displayed, FreeRun mode can be selected by pressing UP key and Lock mode by DOWN key. Tracking Dialog | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 21 Cution : In case the output resolutions are 1600x1200-60Hz, 1080P-50Hz, or 1080P-60Hz, PIP function is not available. So, PIP mode menu will be inactivated for the output resolutions of 1600x1200-60Hz, 1080P-50Hz, or 1080P-60Hz. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 22: Dvi Converter Protocol

    ID: The code to distinguish DVI Converter. It is allocated in the rage of "101"~"109." VIDEO Ch1/Ch2: The classification code for "Channel1" is "0x01", "Channel2" for "0x00. " (Dynamic value) ETX (0x03): The end of Protocol. (Fixed value) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 23 * It is recommended not to give the other command or change the resolution during transmission. * ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 24: Test Pattern

    * ID range (Program): 0x65(101) ~ 0x6D(109) send the command again. * Ch1/Ch2: Channel1 (0x01), Channel2 (0x00) * It is recommended not to give the other command or change the resolution during transmission. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 25 The command for changing PIP Input mode without screen scaling. It is available only for PIP mode during Power on status. → PIP Position Command transmission (to Ch1) PIP Position Response transmission (from Ch1) ← | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 26 1024x768(85Hz) (0x09), 1280x1024(50Hz)(0x0A), 1280x1024(60Hz) (0x0B), 1600x900(50Hz) (0x0C), * ID range (Program): 0x65(101) ~ 0x6D(109) 1600x900(60Hz) (0x0D), 1600x1200(50Hz) (0x0E), 1600x1200(60Hz) (0x0F), 1706x960(60Hz) (0x10), * Ch1/Ch2: Channel1 (0x01), Channel2 (0x00) 1080P(50Hz)(0x11), 1080P(60Hz)(0x12) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 27 → * Status Auto-Calibration Command transmission (to Ch1) Auto-Calibration Response transmission (from Ch1) ← Screen (0x01), White (0x02), Red (0x03), Green (0x04), Blue (0x05), 8-Color (0x06), 10%-White (0x07), 16-Gray (0x08) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 28 / Actual Value (-23 ~ +10) / Actual Value + 127 (0x7F) Pixel Start range: 77(0x4D) ~ 167(0xA7) / Actual Value (-50 ~ +40) / Actual Value + 127 (0x7F) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 29 * It is recommended not to give the other command or change the resolution during transmission. * Check Sum: Add all the values of “STX ~ Data” and execute “Not” operation. * ALL DVIC command is executed Channel2 and Channel1 sequentially. (Channel2 → Channel1) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 30 1: On, 2: Off Year: 2 byte, Month: 2byte, Day: 2byte, Rev: 1byte 15~21 F/W Version 7 byte Ex) December 29th, 2012 Rev. 2→ 0x01 0x02 0x01 0x02 0x02 0x09 0x02 | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 31 Get Picture Control Data Response transmission → ← (to Ch2) (from Ch2) Get Picture Control Data Command transmission Get Picture Control Data Response transmission → ← (to Ch1) (from Ch1) | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 32: Specification

    Select Hot Key, Navigation Key(OSD), Control Channel Select, Communication Method Select. Input Souce, Output Resolution, Key Lock Status Display STN LCD 2X16 Display ※ Specification can be changed without prior notice to improve product quality. | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 33 DVI Converter Infinitely Expandable ODC-10000 MEMO MEMO | ORION PDP CO., LTD. ORION PDP CO., LTD. |...
  • Page 34 DVI Converter Infinitely Expandable ODC-10000 MEMO MEMO | ORION PDP CO., LTD. ORION PDP CO., LTD. |...

Table of Contents