FujiFilm FinePix6800Zoom Service Manual page 59

U/e/eg_model
Hide thumbs Also See for FinePix6800Zoom:
Table of Contents

Advertisement

FinePix6800Zoom(U/E/EG) SERVICE GUIDE
Page Add Purpose
4
C3h
E_SG12
4
C4h
E_OFD_B
Basic notification data
4
C5h
E_OFD_T
4
C6h
E_TEST_QLT
4
C7h
E_TEST_IDX_H
4
C8h
E_TEST_IDX_L
4
C9h
E_TEST_TGV_H
4
CAh
E_TEST_TGV_M
4
CBh
E_TEST_TGV_L
4
CCh
E_TEST_LIM
4
CDh
E_LA2G_A
4
CEh
E_LA2R_A
4
CFh
E_LA2B_A
4
D0h
E_LA2MINRG
4
D1h
E_LA2MAXRG
4
D2h
E_LA2MINBG
4
D3h
E_LA2MAXBG
4
D4h
E_L2LMINRG
4
D5h
E_L2LMAXRG
4
D6h
E_L2LMINBG
4
D7h
E_L2LMAXBG
4
D8h
E_IN_EXW0
4
D9h
E_IN_EXW1
4
DAh
E_L2LG_A
4
DBh
E_L2LR_A
4
DCh
E_L2LB_A
4
DDh
E_L3LG_A
4
DEh
E_L3LR_A
4
DFh
E_L3LB_A
4
E0h
E_SYNCG_A
4
E1h
E_SYNCR_A
4
E2h
E_SYNCB_A
4
E3h
Test
E_TEST_OSD
4
E4h
E_ALN_BVMAX
4
E5h
E_ALN_AVR
4
E6h
E_ALN_EV
4
E7h
E_ALN_ERIA
4
E8h
E_ALN_WGT
4
E9h
E_AVR_WGT
4
EAh
E_SPT_WGT
4
EBh
E_TH_EXNWL
4
ECh
E_TH_EXNW_CNT
4
EDh
E_DACENCTEST
4
EEh
E_EXP_XTG
4
EFh
E_READ_XTG
4.Adjustments and Check
Name
For SG
OFD bottom voltage
OFD top voltage
QLT value for fixed length examination
IDX value (high) for fixed length examination
IDX value (low) for fixed length examination
TGV value (high) for fixed length examination
TGV value (mid) for fixed length examination
TGV value (low) for fixed length examination
LIM value for fixed length examination
WBG <adjustment value> at lamp 2 auto
WBR <adjustment value> at lamp 2 auto
WBB <adjustment value> at lamp 2 auto
Lamp 2 detection frame X1
Lamp 2 detection frame X
Lamp 2 detection frame Y1
Lamp 2 detection frame Y
Fluorescent lamp daylight color low temperature detection frame X1
Fluorescent lamp daylight color low temperature detection frame X2
Fluorescent lamp daylight color low temperature detection frame Y1
Fluorescent lamp daylight color low temperature detection frame Y2
Indoor-like white membership 1
Indoor-like white membership 2
WBG <adjustment value> at fluorescent lamp daylight white color low color temperature auto
WBR <adjustment value> at fluorescent lamp daylight white color low color temperature auto
WBB <adjustment value> at fluorescent lamp daylight white color low color temperature auto
WBG <adjustment value> at fluorescent lamp 3 daylight white color low color temperature auto
WBR <adjustment value> at fluorescent lamp 3 daylight white color low color temperature auto
WBB <adjustment value> at fluorescent lamp 3 daylight white color low color temperature auto
Automatic daytime synchro WBG <adjustment value>
Automatic daytime synchro WBR <adjustment value>
Automatic daytime synchro WBB <adjustment value>
OSD test (00h: Normal, 10h: OFF, 2*h: Test)
Absolute brightness conditions for high-brightness independent point detection, EVx10
Overall average comparison value for high-brightness independent point detection, EVx10
Brightness range for high-brightness independent point detection, EVx10
Contiguous area limit for high-brightness independent point detection, number of areas
Reduction coefficient for high-brightness independent point detection, EVx10
Addition coefficient for overall average metering
Addition coefficient for spot metering
Intermediate evaluation threshold value for evaluation
Daylight white - number of threshold values in white frame
DAC, ENC test
XTG generation position (H1 number) at photography exposure (1/4 drive exposure)
XTG generation position (H1 number) at photography read (1/1 drive read)
Function (Contents)
Initial Adjustment
value
value
00h
00h
O
00h
O
00h
0Bh
1Ch
03h
A9h
80h
FAh
24h
O
2Ch
O
38h
O
78h
C8h
14h
46h
35h
46h
49h
5Ah
0Ah
0Dh
24h
O
3Eh
O
33h
O
24h
O
3Ch
O
3Ah
O
24h
O
3Dh
O
2Ah
O
00h
78h
14h
0Ah
04h
11h
1h
1h
80h
0Ah
00h
04h
50h
59