3
INDOOR / OUTDOOR CORRESPONDENCE TABLE
There is no combination other than this table.
4

SPECIFICATION

Outdoor model
Outdoor unit power supply
Indoor unit No.
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P)
Model
Output
Winding
resistance(at20:)
Model
Winding
resistance(at20:)
Dimensions WOHOD
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity(R22)
Refrigerating oil (Model)
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor
Outdoor
MUX-19TV-
E1
A:07, B:12
Opetate 1 unit
kW
R/h
K /h
A
6.01
A
1,280
W
A(kW)
92.6
%
A
5.68
A
0.33
A
2.65
W
"
"
mm
kg
dB
rpm
kg
cc
DB27°C / WB19°C
DB35°C / WB(24°C)
OUTDOOR UNIT
MUX-20TV-
A:09, B:09, C:09
MUX-19TV -
Single phase
230V, 50Hz
Opetate 1 unit
A
3.5
1.6
Hi:2,460 / Lo:1,920
RH220VHAT (Room A) / RH135VHAT (Room B)
1,050 / 650
C-R 2.13/4.18
C-S 3.91/5.76
RA6V60-DA
WHT-BLK 90 BKL-YLW 54
BLK-RED 146
840 640 330
High:730 / Low:580
Room A : 0.87
Room B :1.0
520(MS56) / 300(MS56)
3
MUX-25TV-
E1
A:12, B:12
E1
Opetate 2 unit
B
2.2
0.8
15
3.33
745
97.3
45.6
3.00
0.33
2.82
63
52
2
E1
A+B
3.5+2.2
1.6+0.8
8.94
2,005
97.5
8.37
0.57
2.74