Spark Plug; Muffler; Cooling System - Husqvarna 375K Operator's Manual

Power cutter
Hide thumbs Also See for 375K:
Table of Contents

Advertisement

Spark plug

The condition of the spark plug
is affected by:
• An incorrect carburettor
setting.
• An incorrect fuel mixture
(too much oil).
• A dirty air filter.
These factors cause deposits
on the spark plug electrode
that may result in malfunction
or starting difficulties.
• If the machine is low on
power, difficult to start or
runs poorly while idling
always check the spark
plug first. If the spark plug
is dirty, clean it and at the
same time check that the
electrode gap is 0,5 mm
(.020"). The spark plug
should be changed after
about one month of
operation or earlier if
necessary.
NOTE! Always use the recommended type of spark plug. (see
chapter "Technical data" )! An incorrect spark plug can damage
the cylinder/piston.

Muffler

The muffler is designed in
order to reduce the noise level
and to direct the exhaust
gases away from the operator.
The exhaust gases are hot
and can contain sparks, which
may cause fire if directed
against dry and combustible
material.
Never use a saw with a
clogged or defective muffler.
20
– English
MAINTENANCE

Cooling system

To maintain as low an operating temperature as possible the
power cutter is equipped with a cooling system.
The cooling system consists of:
0,5 mm
1. An air intake on the
2. Air flow guide.
3. Cooling fins on the
4. Cooling fins on the
5. Cylinder cover (leads cold
Clean the cooling system
using a brush at least once
a week, in difficult
conditions more often. A
dirty or blocked cooling
system leads to the engine
overheating resulting in
damage to the cylinder and
piston.
starter unit.
flywheel.
cylinder
air onto the cylinder).
5
4
3
2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

371k

Table of Contents