USING ADJACENT STUD SPACE FOR ALL
COMBUSTION AIR FROM OUTSIDE
HOLES CONNECTING TO
VENTILATED ATTIC
HOLES CONNECTING TO VENTILATED
CRAWL SPACE
BASED ON 4,000 BTU OF TOTAL INPUT RATING
OF ALL GAS APPLIANCES, THE HEATER ONLY
REQUIRES A MINIMUM FREE AREA OF:
SQUARE
BTU
IN.
25,000
6.25
35,000
8.75
50,000
12.50
55,000
13.75
65,000
16.25

ROUGH-IN INSTRUCTIONS

In selecting a location for installation, it is necessary to
provide adequate accessibility clearances for servicing
and proper operation.
Minimum clearance from cabinet to combustible
construction:
Side Wall
Floor
Ceiling
See Figure 2. The unit may be recessed and rest
directly against side studs and the inside surface of the
rear wall.
ELECTRICAL ROUGH-IN
Rough in 115 v. wiring, terminating inside the junction
box located on top of header plate for recessed, or in
a receptacle box (not provided) for flush mount.
Consult local codes or ordinances. See Figure 3.
MODEL NUMBER
CF353C, CF354C
CF503C, CF504C
CF653C, CF654C
CF357C
CF358C
CF557C
CF558C
CEILING
PLATE
AIR
GRILLE
FLOOR
PLATE
HOLE
SQUARE
SIZE =
IN.
1"
.785
1.5"
1.76
2"
3.14
2.5"
4.90
3"
7.065
-
4"
-
0"
-
4"
AMPS
1.95
2.25
2.25
2.2
2.25
2.5
2.55
LOCATION AND SPECIAL PRECAUTIONS
The wall furnace should be located near the center of
the house for best heat distribution.
If the area where the appliance is to be installed contains
carpeting, tile or combustible materials, other than wood
flooring, the appliance shall be installed on a metal plate,
wood panel or other non-combustible materials. The use
of ceramic or quarry tile is acceptable and will provide a
surface that is easily cleaned. This material is to extend
the full width and depth of the appliance. If side or rear
warm air outlets are being installed, see figure 14 – 18,
See page 16 and 17.
FIGURE 2
115 V.A.C.
Line
In
Wire Nut (not provided)
Switch Box Cover Plate
FIGURE 3
Page 6
4" Minimum
4" Minimum
B-W Vent
Pipe
Header Plate
2x4
Stud