Default Thermostat Settings
Default thermostat settings are shown in table 2 and the
default program is shown in table 3.
Table 2. Default Thermostat Settings
Mode
Setpoint
Fan
Filter Reminder
Maintenance Reminder
Equipment Protection
Timers
Table 3. Default Program Settings
Programs
Time
Weekday − A 6:00am
Weekday − B 8:00am
Weekday − C 6:00pm
Weekday − D 10:00pm 62_F / 17°C
Weekend − A 6:00am
Weekend − B 8:00am
Weekend − C 6:00pm
Weekend − D 10:00pm 62_F / 17°C
Weekday
Monday, Tuesday, Wednesday,
Thursday, Friday
Weekend
Saturday, Sunday

Technical Specifications

Thermostat Type
Electronic programmable thermostat for heat pump,
3-stage heat/2-stage cool.
NOTE − 2 stages of heat pump heat and one stage of auxil-
iary (gas or electric) backup heat are supported.
Power Supply Range
18VAC − 30VAC (24VAC nominal), 60Hz
506074−01 02/08
Heat (Permanent Hold
Mode)
70°F (or 21°C)
Auto
OFF
OFF
Reset Back to Zero
Temperature
Temperature
(Heat)
(Cool)
70_F / 21°C
78_F / 26°C
62_F / 17°C
85_F / 29°C
70_F / 21°C
78_F / 26°C
82_F / 28°C
70_F / 21°C
78_F / 26°C
62_F / 17°C
85_F / 29°C
70_F / 21°C
78_F / 26°C
82_F / 28°C
24VAC is present on the terminals of the thermostat
bracket. If removing the thermostat from the wall,
use caution and avoid touching any of the connec-
tor terminals on the wall bracket.
Also, when working with the thermostat dip
switches, use a non−conductive tool and take cau-
tion to avoid making any contact with the circuit
board, its imprinted circuitry and its connector
prongs.
Temperature Display
Display Scale: Fahrenheit or Celsius user selectable (via
DIP switch; see figure 22)
Display range: 35°F (2°C) to 99°F (37°C)
Display resolution: 1°F (1°C)
Display Accuracy: +/−1°F
If the Fahrenheit/Celsius display must be changed, use a
plastic, non−conductive tool to push the dip switch to the
right position (see figure 22).
1
2
3
4
5
PLUG IN (Use Care To Avoid Bending Prongs.)
6
F/C (Fahrenheit/Celsius) switch
shown in Celsius position
Figure 22. Changing Fahrenheit/Celsius Setting
Temperature Measurement Range
Measurement Scale: Fahrenheit
Measurement Range: 35°F to 99°F
Measurement Resolution: 0.5°F
Measurement Accuracy: +/−1°F
Field Offset: via DIP switches to +/−3°F
Sampling Method: temperature measurements sampled
every 15 seconds. Displayed temperature is the average
of the last four measurements.
Temperature Setpoint Range
Setting range: 50°F (10°C) to 90°F (32°C)
Setting resolution: 1°F (1°C)