Mitsubishi Electric MSZ-SF25VE Service Manual page 34

Hide thumbs Also See for MSZ-SF25VE:
Table of Contents

Advertisement

OPERATING PROCEDURE
6. Removing the indoor fan motor, the indoor coil
thermistor and the line flow fan
(1) Remove the panel (Refer to 1.) and the corner box
right.
(2) Remove the indoor electronic control P.C. board
holder, the electrical box and the nozzle assembly.
(3) Remove the screws fixing the motor bed.
(4) Release the hooks of the water cut and remove the
water cut.
(5) Loosen the screw fixing the line flow fan.
(6) Remove the motor bed together with the indoor fan
motor and the motor band.
(7) Release the hooks of the motor band and remove the
motor band. Pull out the indoor fan motor.
(8) Remove the indoor coil thermistor from the heat
exchanger.
Install the indoor coil thermistor in its former position
when assembling it (Photo 5.).
(9) Remove the screws fixing the left side and the upper
right side of the heat exchanger (Photo 7, Photo 5).
(10) Lift the heat exchanger, and pull out the line flow fan
to the lower-left.
© Copyright 2011 MITSUBISHI ELECTRIC CORPORATION
Distributed in Aug. 2013. No. OBH600 REVISED EDITION-B
Distributed in Nov. 2012. No. OBH600 REVISED EDITION-A
Distributed in Nov. 2011. No. OBH600
Made in Japan
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
PHOTOS
Photo 5
Lead wire of the
indoor coil thermistor
Water cut
Photo 6
Screw of the line flow fan
Photo 7
Screws of
the left side of
the heat exchanger
New publication, effective Aug. 2013
Specifications are subject to change without notice.
Screw of
the upper
side of
the heat
exchanger
Screws of
the motor bed

Hide quick links: