a) remove the cooler sensor from the support and
remove the 3 fixing screws from the fan;
In case of replacement of the fan it is necessary to be sure that the fan operates with suction.
To simulate the door closed use a magnet and put it next to the reed element.
COMBI ZERO DEGREE REFRIGERATOR
5. Fan and cooler sensor
b) the fan cables must pass inside the slit (A) in the fan
support;