9.3.4 Temperature protection of compressor exhaust.
If the exhaust temp. of compressor is higher than 115℃ and lasts for 5 seconds, the compressor stops and
does not resume until the exhaust temp. is lower than 90℃.
9.3.5 Inverter module Protection, Inverter module Protection itself has a protection function against current, voltage
and temperature. If these protections happened, the corresponding code will display on indoor unit LED.
9.3.6 Sensor protection at open circuit and breaking disconnection
9.3.7 Fan Speed is out of control. When Indoor Fan Speed is too low (lower than 300RPM for 60 seconds), the unit
stops and LED displays failure information and can't return to normal operation automatically.
9.3.8 Cross Zero signal error warning. If there are 20 alternations of Cross Zero signals are incorrect, the unit stops
and LED displays failure information. After resuming, the motor rotates again. The spacing of Cross Zero signal
is 6-13ms.
9.3.9 Indoor fan delayed open function
9.3.10 For all modes, when the units are turned on, the indoor fan can operate 10 seconds after the action of
louver.
9.3.11 Compressor preheating function.
1) Preheating permitting condition:
If T4(outdoor ambient temperature)<3℃ and the machine connects to power supply newly or if
T4<3℃
and compressor has stopped for over 3 hours, the compressor heating cable will work.
2) Preheating mode:
A weak current flows through the coil of compressor from the wiring terminal of compressor, then
the
compressor is heated without operation.
3) Preheating release condition:
If T4>5℃ or user turns on the machine and compressor runs, preheating function will stop.

9.4 Fan-Only Mode

9.4.1 Temperature setting function is disabled, and no setting temperature display.
9.4.2 In this mode, the action of louver is the same as in cooling mode.
9.4.3 The action of auto fan in fan-only mode is the same as auto fan in cooling mode with 24℃ setting
temperature.
3.5
3.0
1.5
1.0
high
medium
low
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mtn a235dvMtg a235dv

Table of Contents