Electrolux Eurocombi Service Manual page 9

Table of Contents

Advertisement

Defrosting heater:
Drainage duct heater:
Safety overheating switches:
Settings for refrigerator compartment:
thermostat knob
* in this position, the thermostat completely blocks the passage of cold air coming from the freezer
compartment.
Settings for freezer compartment:
Position of
thermostat knob
Normal operating times:
** A six-hour operating cycle is performed each time the appliance is switched on.
Defrosting:
Eurocombi
Power at 230V
Power at 230V
aperture
closure
Position of
stand by*
3
5
7
Cut-in
0
-15 °C
3
-18 °C
5
-21°C
7
-23°C
pre-determined**
minimum
maximum
standard time
maximum time
temp. for end of defrosting
W
W
°C
°C
Cut-in
Flap closed
+10 °C
+7°C
+4°C
Cut-out
-16°C
-19°C
-22°C
-24°C
hrs
hrs
hrs
minutes
minutes
°C
250
43.5
55
45
Cut-out
Flap closed
+7°C
+4°C
+1°C
Alarm
-12°C
-12°C
-12°C
-12°C
6
4
25
22
30
+15
9/32

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents