RS-232 terminal Product Interface specifications

Communication configuration
To control the projector from an LCD control panel, connect an RS-232 cable to
the serial control connector on the projector and set your computer's serial port
settings to match this communication configuration:
Setting
Bits per second
Data bits
Parity
Stop bits
Flow control
Emulation
Command format
All commands consist of 3 alpha characters followed by a request, all enclosed in
"greater than" and "less than" signs. The request can be a read request (indicated
by a "?") or a write request (indicated by 1 to 4 ASCII digits).
A read request format: <AAA?> where
<
AAA
?
>
Value
115,200
8
None
1
None
VT100
starts the command
denotes the command
denotes the read request
ends the command
A write request example: <AAA=####> where
Some commands have ranges, while others are absolute. If a number greater than
the maximum range is received, it is automatically set to the maximum number for
that function. With absolute settings, "0" is off, 1-9999 is on. The one exception is
the Power command, where 0 is off and 1 is on
Refer to the support section of our website for detailed information on the Prod-
uct Interface formats.
31
<
starts the command
AAA
denotes the command
=####
denotes the value to be written
(leading zeros not necessary)
>
ends the command
.