4.7
INITIAL SETTING VALUES IN THE SERVICE MODE
• Perform fine-tuning based on the "initial values" using the remote control when in the Service mode.
• The "initial values" serve only as an indication rough standard and therefore the values with which optimal display can be achieved
may be different from the default values. But, don't change the values that are not written in "ADJUSTMENT PROCEDURE". They
are fixed values.
NOTE:
As for the items whose settings are "Fixed" in Table 1 in "3.3 REPLACEMENT OF MEMORY IC", the following tables show initial
values in NTSC signal input mode. As for the items whose conditions of SETTING VALUE are not written in the following tables,
the following tables show initial values in NTSC signal input mode.
• Among the initial values, there are some that are displayed "( )"as offset values. These are values relative to the base or absolute
values. Set the values by addinG offset values to the base values. Base values are displayed as "---".
4.7.1 [1.PICTURE/SOUND]
Item
Item
No.
A01
(Not display)
A02
(Not display)
A03
(Not display)
A04
(Not display)
A05
(Not display)
A06
(Not display)
A07
(Not display)
A08
(Not display)
A09
(Not display)
A10
(Not display)
A11
(Not display)
A12
(Not display)
A13
(Not display)
A14
(Not display)
Item
Item
No.
S01 COLOR
S02 TINAD
S03 OF COLOR
S04 OF TINAD
Item
Item
No.
S05 BRIG
S06 CONT
S07 OF BRIG
S08 OF CONT
1-26 (No.YA029)
Variable
Setting value
range
000~007
003
000~007
003
000~007
003
000~007
004
000~015
009
000~015
006
000~015
006
000~015
003
000~007
006
000~007
004
000~063
063
000~063
063
000~003
000
000~007
000
Variable
NTSC
range
STANDARD THEATER STANDARD THEATER STANDARD THEATER STANDARD THEATER
000~255
140
135
000~255
000
000
-127~128
(---)
(---)
-127~128
(---)
(---)
Variable
NTSC
range
STANDARD THEATER STANDARD THEATER STANDARD THEATER
000~255
038
038
000~255
125
125
-127~128
(---)
(---)
-127~128
(---)
(---)
Item
Item
No.
A15
(Not display)
A16
(Not display)
A17
(Not display)
A18 IN LEVEL
A19 LOW SEP
A20 HI SEP
A21 AHS MVE
A22 AHS MSC
A23
(Not display)
A24
(Not display)
A25
(Not display)
A26
(Not display)
A27
(Not display)
Setting value
525i
525p
140
130
140
000
000
000
(---)
(---)
(---)
(---)
(---)
(---)
Setting value
525i/525p
750p/1125i
044
040
043
128
128
128
(---)
(---)
(---)
(---)
(---)
(---)
Variable
Setting value
range
000~003
000
000~003
000
000~003
000
000~255
(Not used)
000~255
(Not used)
000~255
(Not used)
-128~+127
000
-128~+127
000
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
000~001
(Not used)
750p/1125i
130
148
000
000
(---)
(---)
(---)
(---)
038
128
(---)
(---)
140
000
(---)
(---)