Table Of Contents; Product Dimensions; Duct Cover Accessories; Product Clearances - GE Monogram ZV1050 Installation Instructions Manual

42" island vent hood
Hide thumbs Also See for Monogram ZV1050:
Table of Contents

Advertisement

CONTENTS
Product Dimensions ......................................................... 3
Duct Cover Accessories .................................................... 3
Product Clearances .......................................................... 3
Tools and Materials Required .......................................... 4
Power Supply .................................................................... 4
Duct Fittings ...................................................................... 5
Ceiling Support Structure ...................................... 6
Ductwork ................................................................. 7

PRODUCT DIMENSIONS

This vent hood is designed to be used in vented ceiling
mounted installations.
31-1/2"
* 20" to an 8 ft. ceiling.
Using supplied duct cover
32" for 9 ft. Ceiling.
Using ZX1059SFSS Accessory
44" for 10 ft. Ceiling
Using ZX10510SFSS Accessory
This vent hood is supplied with a decorative duct cover to
reach 8 ft. ceiling height, or between 7'11" and 8'1".

DUCT COVER ACCESSORIES

Order Accessory duct covers for 9 ft. and 10 ft. ceilings.
ZX1059SFSS - For 9 ft. ceiling height
This kit includes a decorative duct cover and support
frame to reach a 9 ft ceiling height.
ZX10510SFSS - For 10 ft. ceiling height
This kit includes a decorative duct cover and support
frame to reach a 10 ft ceiling height.
Order the accessory at the same time as the vent hood
and have on site before installation begins.
Design Information
*Height
to Ceiling
10"
42"
Step 2, Remove Packaging ............................................... 8
Step 3, Check Installation Hardware ............................... 8
Step 4, Mount Template ................................................... 9
Step 5, Install Support Frame .......................................... 9
Step 6, Secure Wiring ..................................................... 10
Step 7, Size and Install Ductwork .................................. 10
Step 8, Install Decorative Duct Covers .......................... 11
Step 9, Install Hood ........................................................ 11
Step 10, Connect Electrical ............................................ 12
Step 11, Slide Duct Cover Down .................................... 12

PRODUCT CLEARANCES

The vent hood must be installed 25-1/2" min. and 30"
max. above the cooking surface. 30" is recommended
for 8 ft. ceilings. 30" clearance will insure that the duct
cover meets the ceiling. The cooking surface should be
at least 36" above the floor. Installation will be easier if
the vent hood is installed before the cooktop and
countertop is installed.
*9 ft. to 10 ft. ceilings may be 25-1/2" to 30" clearance.
*The distance between the cooking surface and the bottom of the
hood must be at least 25-1/2". The 30" recommended installation
height, above the standard 36" countertop, will insure duct cover fit
to the ceiling. For 9 ft and 10 ft. ceilings, the hood may be lowered to
25-1/2" over the cooking surface.
IMPORTANT: Clearances may vary due to type of cooking product
and local codes. Check with local inspectors to be sure standard is
applicable.
- When installing the Island Hood above a Monogram Professional
Range or Cooktop, installation clearance must be at least 30".
3
*30"
Recommended
36" Min.