5

SPECIFICATION

Outdoor model
Outdoor unit power supply
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity [Rated (Min.-Max.) Hz]
Dehumidification
Outdoor air flow
Breaker capacity
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P)
Model
Output
Winding
resistance (at 20 °C)
Model
Winding
resistance (at 20 °C)
Dimensions W x H x D
Weight
Sound level (High/Low)
Fan speed (High/Low)
Fan speed regulator
Refrigerant filling
capacity (R410A)
Refrigeration oil (Model)
NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
•Refer to 3 "INDOOR/OUTDOOR CORRESPONDENCE TABLE" for the combination.
1 Measured under rated operating frequency.
2 Electrical data is for only outdoor unit.
3 These specifications are when all indoor units are operating.
TEST CONDITIONS COOLING INDOOR
HEATING INDOOR
m
m
m
m
kW
/h
m
3
/h
A
A
W
%
A
A
A
2
E1
E2
W
Ω
Ω
mm
kg
dB
rpm
kg
cc
Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C
OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C
Dry-bulb temperature 20.0°C
OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C
MXZ-2A30VA
Single phase
230 V, 50 Hz
2
Max. 20
Max. 15
Refer to 9
Refer to 9
Cooling
3.0 (1.1 - 4.0)
1,950
10
2.87
595
90
3.60
2.67
0.2
5.04
KNB092FEDH
KNB073FGDH
750
U-V 1.70
V-W 1.70 W-U 1.70
RC0J50-CF
BLK-WHT 14.2
WHT-RED 14.2 RED-BLK 14.2
800 x 550 x 285
34
46/44
850/650
2
1.15
320 (NEO22)
61
Heating
4.0 (1.0 - 4.5)
1,950
3.6
745
3.40
5.37
47/46
850/650