• Easy ‘How to use’ guides for storage heaters • Service and repairs • Where to buy our products • Literature downloads • Heating requirement calculator Visit ‐ www.dimplex.co.uk/support A division of GDC Group Ltd Registered No: 1313016 England VAT GB 287 1315 50004 Millbrook House Grange Drive Hedge End Southampton SO30 2DF EEE Producer Registration Number –...
Page 2
Langbrook 5kW Clean Burn Stove (LBK5SE) Please hand these instructions to the stove user when installation is complete. Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls. Installation should only be carried out by a suitably qualified installer that is registered with HETAS (UK) or with the Irish Nationwide Fireplace Organisation (INFO).
K (Dia) Table 1 - Dimensions Langbrook 5kw Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”) Table 2 - Technical Specification Langbrook 5kw Wood Nominal heat output Solid Fuel (Ancit) Wood 77.0 Efficiency...
Page 4
Solid, non-combustible material e.g. masonary or concrete See Table 3 150mm 125mm Table 3 - Position of Hearth & Appliance from adjacent walls Hearth distance ‘X’ from wall Appliance distance from walls Min Wall Thickness ‘T’ Min Wall height ‘H’ 0 - 50mm 200mm Height of appliance +300mm...
Page 5
CLOSURE Seal gap with SEAL 150 max PLATE fire-proof lagging 150 max...
- 1 - Langbrook 5kW Clean Burn Stove (LBK5SE) IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Health and Safety Precautions Important Safety Advice Handling: Adequate facilities must be available for the unloading Please read these instructions carefully before installing and handling of this appliance.
Page 7
- 2 - Flue Deposits In all cases allow an apron of at least 300mm at the front of the stove in case of spills when de-ashing. If the chimney was previously used as an open fire, it is possible that the higher flue gas temperatures generated by the stove Table 5 shows the minimum safe distances to combustable may loosen deposits that were previously adhered to the inner...
- 3 - with all windows and doors shut in the room where the appliance The stove can be banked up for long periods. When burning solid is fitted. fuel empty the ash pan. Open air controls and let the fire burn brightly for a short period.
- 4 - Safety Notes for Your Guidance Troubleshooting FIRES CAN BE DANGEROUS. 1. Poor heat output Always use a fire guard in the presence of children, the elderly a. Stove too small for room: Seek advice from a Qualified Heating or the infirm.
Act to authorise smokeless fuels or exempt It is a condition of the guarantee that only genuine Dimplex spare appliances for use in smoke control areas in England. In Scotland parts are used. Parts that may need occasional replacement are and Wales this power rests with Ministers in the devolved fire bricks, ashpan, grate and log retainer.
Langbrook 5kW (LBK5SE) LANGBROOK 5KW STOVE (LBK5SE) - SPARE PARTS Item Description Part Number Item Description Part Number DOOR 3011102 BAFFLE PLATE 3011117 DOOR HINGE 3011103 ASHPAN 3011118 HINGE MOUNT 3011104 PRIMARY AIR SLIDE 3011119 DOOR HANDLE 3011105 PRIMARY AIR HANDLE...
Page 13
TEL: 0845 600 5111 DIMPLEX FAX: 01489 773050 MILLBROOK HOUSE WEBSITE: www.dimplex.co.uk GRANGE DRIVE HEDGE END Republic of Ireland Tel: 01 842 8222 SOUTHAMPTON SO30 2DF [c]A Division of GDC Group Ltd. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of...